Maintenance and service
Removing device covers
The maintenance work should be
carried out annually. The heat
exchanger does not have to be cleaned
if there is a small amount of dirt, but
must be cleaned at least every two
years.
Maintenance and cleaning work is
only performed by the authorised
expert. He is responsible for correct
maintenance.
Before the maintenance work,
remove the device from the mains
electricity and close the feed and
reflux.
Removing the boiler covers
x
Loosen 2 screws (1) on the front
cover
(2)
x
Slide the front cover up and
remove
x
Loosen the tension fasteners (3)
on the side cover (4)
x
Fold the side cover to the right and
left and lift from the clips (5)
x
Open the snap fastener (6) on the
front cover plate (7)
x
Remove the cover plate
2
1
1
3 3
4
4
5
6
7
1.
2.
4
22