REBLE610 Fully indoor Microwave Link
Page 47 of 52
Version 1.4
Figure 87: Web slot Rx form – RSSI Graphic.
RSSI Graphic frame reports the received signal strength trend of last 190 days with 5 seconds sampling
time.
Figure 88: Web slot Rx form – Frequency.
Frequency frame let the user change the receiver frequency, depending on the factory limits (shown in the
interactive bar); by default, it is possible to modify the frequency in a +/- 5 MHz range (channel filter is
generally installed).
Figure 89: Web slot Rx form –Temperature Management.
Temperature management frame reports transmitter board temperature trend of last 10 days, with 5
seconds sampling time. Furthermore, it is possible to set and check alarm and warning thresholds (through
the interactive bar and the
Apply
button), and the actual temperature.
.