REBLE610 Fully indoor Microwave Link
Page 32 of 52
Version 1.4
Overflow error
Data buffer overflow indication.
Underflow error
Data buffer underflow indication.
Figure 54: Web Status form – Interface Loop.
Furthermore, REBLE610 offers the possibility of an “internal loop” of data received by demodulation
section, redirecting towards modulator section. In Figure 55 this function management is shown.
8.2.1
Status-Transmitter.
Figure 55: Web Status form – Tx.
This form is not available in half duplex configuration, receiver version.
Table 14: Status Transmitter.
Model
Transmitter board model.
Version
Transmitter board HW version.
Revision
Serial number transmitter board.
Temperature
Transmitter board temperature measurement. Line is green if
value is between limits, red otherwise.
Frequency
Transmitting circuit operating frequency.
Power
Transmitter output power. Line is green if value is between
limits, red otherwise.