background image

 
 

w w w . e l a t i o n l i g h t i n g . c o m  

 

                                                                                              17

                                           

VOLT Q5E™ User Manual ver 2 

DMX ADDRESSING 

All fixtures should be given a DMX starting address when using a DMX controller, so 
the correct fixture responds to the correct control signal. This digital starting address 

is the channel number from which the fixture starts to “listen” to the digital control 
information  sent  out  from  the  DMX  controller.  The  allocation  of  this  starting  DMX 

address  is  achieved  by  setting  the  correct  DMX  address  on  the  digital  display 
located on the back of the fixture. 

 

You  can  set  the  same  starting  address  for  all  fixtures  or  a  group  of  fixtures,  or  set 
different address for each individual fixture. Be advised that setting all fixtures to the 

same DMX address will subsequently control all fixtures in the same fashion, in other 
words, changing the settings of one channel will affect all the fixtures simultaneously. 

 

If you set each fixture to a different DMX address, each unit will start to “listen” to the 
channel  number  you  have  set,  based  on  the  quantity  of  control  channels  (DMX 

channels) of each fixture. That means changing the settings of one channel will only 
affect the selected fixture. 

 

In the case of the 

VOLT  Q5E™

, when in the 

9  Channel  Extended  Mode

 you should 

set the starting DMX address of the first unit to 1, the second unit to 10 (1 + 9), the 
third unit to 19 (10 + 9), and so on. 

 

Note: 

During start-up the 

VOLT Q5E

 will automatically detect whether a DMX data 

signal is being received or not. If DMX data signal is being received, the display will 

show 

"Addr=XXX" 

(

XXX 

representing  the  actual  DMX  address).  If  the  fixture  is  not 

receiving  a  DMX  signal  the  display  will  flash.  If  your  fixture  is  connected  to  a  DMX 

controller and the display is flashing (not receiving a DMX signal), please check the 
following:

 

-    The  3pin  XLR  input  plug  (cable  with  DMX  signal  from  controller)  is  not 

connected or is not inserted completely into the DMX input jack of the fixture. 

-

 

The DMX controller is switched off or defective. 

-

 

The DMX cable or connector is defective. 

-

 

A DMX terminator has been inserted into the last fixture in your DMX chain. 

 

Содержание VOLT Q5E SIX PACK

Страница 1: ...VOLT Q5E SIX PACK user manual E L A TI ON VOLT Q5E SIX PACK user manual...

Страница 2: ...affiliated companies hereby disclaim any and all liabilities for property equipment building and electrical damages injuries to any persons and direct or indirect economic loss associated with the use...

Страница 3: ...arranty 7 Safety Instructions 8 General Guidelines 9 Fixture Overview 10 Battery Charging 11 Fixture Installation 12 Understanding DMX 15 Fixture Menu 18 Internal Wireless DMX Receiver Set Up 26 DMX C...

Страница 4: ...otection The first digit Foreign Bodies Protection indicates the extent of protection against particles entering the fixture and the second digit Water Protection indicates the extent of protection ag...

Страница 5: ...listed below Please do not discard the shipping carton in the trash Please recycle whenever possible BOX CONTENTS 1 VOLT Q5 Charging Road Case powerCON Cable 6 VOLT Q5E Fixtures 6 9 8 ft 3m 3pin IP Fe...

Страница 6: ...ng container If the unit is under warranty you must provide a copy of your proof of purchase invoice Items returned without a R A number clearly marked on the outside of the package will be refused an...

Страница 7: ...r by Elation Professional if the product is damaged because not properly maintained as set forth in the product instructions guidelines and or user manual D This is not a service contract and this war...

Страница 8: ...proper operation follow the Installation guidelines described in this manual Only qualified and certified personnel should perform installation of this fixture and only the original rigging parts bra...

Страница 9: ...ithout knowledge how to do so DO NOT allow operation by persons who are not qualified to operate this type of fixture Most damages are the result of operations by nonprofessionals Consistent operation...

Страница 10: ...al ver 2 F I X T U R E O V E R V I E W 1 LED Lens 2 LCD Menu Display 3 MODE ESC Button 4 UP Button 5 DOWN Button 6 ENTER Button 7 Charge Indicator 8 Wireless DMX Indicator 9 Power Switch 10 Power IN 1...

Страница 11: ...ng on fixture usage and settings install location temperature and number of charge cycles CHARGE TIME Units must be placed in charging road case for a period of 8 hours to fully charge the batteries R...

Страница 12: ...tion mount the fixture in areas outside walking paths seating areas or in areas were unauthorized personnel might reach the fixture Ambient operating temperature range for this fixture is 14 113 F 10...

Страница 13: ...ed omega brackets using a M10 screw fitted through the center hole of the Omega Bracket Be sure to attach the included Safety Cable to the fixture using the safety cable rigging point integrated in th...

Страница 14: ...ic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury Fixture is...

Страница 15: ...ixture to fixture via data IN and data OUT XLR terminals located on the fixtures most controllers will only have output jacks DMX LINKING To ensure proper DMX data transmission always use the VOLT ser...

Страница 16: ...must be used Always be sure daisy chain your in and out data connections never split or Y your DMX connections Address 1 Address 10 Address 19 DMX 512 CONNECTION WITH DMX TERMINATOR A DMX terminator s...

Страница 17: ...ch unit will start to listen to the channel number you have set based on the quantity of control channels DMX channels of each fixture That means changing the settings of one channel will only affect...

Страница 18: ...ton once will access the fixture s main menu Once in the main menu you can navigate through the different functions and access the sub menus with the UP and DOWN buttons Once you reach a field that re...

Страница 19: ...ry Charge Level Soft Ver V1 1 0 Software Version Persnal Stat Set Addr DMX ON OFF Address Via DMX NoDMXSta CloShut Hold Auto Auto Run If No DMX Disp Set Off Time 02 59m 05m Display Shut Off Time Key L...

Страница 20: ...nder EditProg and edit individual scenes under EditScen Info TimeInfo Cur Time Displays fixture run time from last power ON The counter is reset after each time the fixture is powered OFF TotalHrs Dis...

Страница 21: ...t Channel 1 to a value of 7 set Channel 2 to a value of 7 and then set Channel 3 to a value of 57 Example 2 If the desired DMX address is 420 set Channel 1 to a value of 7 set Channel 2 to a value of...

Страница 22: ...e light on a flat surface wall and perform fine adjustments Mode Set UserMode Select operating mode which includes DMX Channel and User defined modes EditProg Sel Prog Select one of the 10 user define...

Страница 23: ...the Slave unit was assigned to If e g a Slave unit is set to Slave 1 in the menu SetSlave the Master unit sends Prog 1 to the Slave unit If set to Slave 2 the Slave unit receives Prog 2 To start an Au...

Страница 24: ...the same program as the master units Press ENTER to confirm Press MODE ESC in order to return to the main menu 4 Program Selection for Edit Program Select EditProg Press ENTER to confirm Select the d...

Страница 25: ...Working With Built In Program continued Example Prog 2 includes scenes 10 11 12 13 Prog 4 includes scenes 8 9 10 Prog 6 includes scenes 12 13 14 15 ProPart1 is Prog 2 ProPart2 is Prog 3 ProPart3 is Pr...

Страница 26: ...onnect a fixture to a controller via a DMX cable when the EWDMX system is in use This could cause serious damage to the controller SETTING UP THE EWDMX SYSTEM Follow the instructions included with the...

Страница 27: ...Transmitter First be sure the fixture s is powered ON and then hold down the configuration button on the WDMX Transmitter for as least 5 seconds This will automatically clear the link between the EWDM...

Страница 28: ...0K 6 6 COLOR MACROS 0 NO Function 1 7 Color Macro 1 8 15 Color Macro 2 16 23 Color Macro 3 24 31 Color Macro 4 32 39 Color Macro 5 40 47 Color Macro 6 48 55 Color Macro 7 56 63 Color Macro 8 64 71 Col...

Страница 29: ...BE 0 31 LEDs OFF 32 63 LEDs ON NO STROBE 64 95 STROBE Effect SLOW to FAST 96 127 LEDs ON NO STROBE 128 159 STROBE Pulse Effect In Sequences 160 191 LEDs ON NO STROBE 192 223 Random STROBE Effect SLOW...

Страница 30: ...authorized Elation service technician Should you need any spare parts please order genuine parts from your local Elation dealer Please refer to the following points during routine inspections A detail...

Страница 31: ...lter Gel Frame Electronic Strobe and Dimming Variable Dimming Curves Multiple Color and Chase Macros CONTROL CONNECTIONS 4 DMX Channel Modes 4 5 11 12 Internal Wireless EWDMX Receiver 4 Button Control...

Страница 32: ...Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice VOLT Q5E DIMENSIONAL DRAWINGS Please Note Specifications and improveme...

Страница 33: ...vy Duty Wrap Around Hook Style Clamp EWD001 EWDMX IP Wireless IP65 DMX Transceiver VOLT5CHARGER VOLT Q5E 26 2 VDC Charger IEC Power Cable VOLT 3MDLC VOLT Series 9 8 ft 3m 3pin Male IP to 3pin Female I...

Страница 34: ......

Отзывы: