background image

 
 
 

ELAR DW BRICK ™

 

 

©Elation Professional, Los Angeles Ca. 

15 

 

www.ElationLighting.com

   

fixture. That means changing the settings of one channel will only affect the selected fixture. 

 

In the case of the ELAR DW BRICK™, which is a 5 channel fixture (default), you 

should set the starting DMX address of the first unit to 1, the second unit to 6 (5 + 1), 

the third unit to 11 (6 + 5), and so on.   

 

Note: 

During start-up the ELAR DW BRICK ™ will automatically detect whether a DMX data 

signal is being received or not. If a DMX data signal is being received, the display will show 

"A.XXX" (XXX 

representing the actual DMX address). If the fixture is not receiving a DMX 

signal the display will flash 

"A.XXX" (XXX 

representing the actual DMX address).   

 

If your fixture is connected to a DMX controller and the display is flashing (not receiving a 

DMX signal), please check the following: 

-   The 3-pin or 5-pin XLR plug (cable with DMX signal from controller) may not be 

connected or is not inserted completely into the DMX input jack. 

-  The DMX controller is switched off or defective. 

-  The DMX cable from the controller merging with included IP Rated Cable adapter is 

not connected securely 

-  The DMX cable or connector is defective. 

-  A DMX terminator has been inserted into the last fixture in your DMX chain. 

 

 

Содержание ELAR DW BRICK

Страница 1: ...Rev 01 06 2011 Version 1 3 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 www elationlighting com...

Страница 2: ...uidelines 7 5 Fixture Overview 8 6 Mounting and Installation 10 7 Understanding DMX 12 a DMX Connections 12 b DMX Terminator 13 c 3 Pin to 5 Pin Conversion 14 d Understanding DMX Addressing 14 8 Displ...

Страница 3: ...ate the fixture have arrived intact In the event damage has been found or parts are missing please contact our customer support team for further instructions Please do not return this unit to your dea...

Страница 4: ...e your purchase All returned service items whether under warranty or not must be freight pre paid and accompany a return authorization R A number The R A number must be clearly written on the outside...

Страница 5: ...Operating the ELAR DW BRICK without suited safety aids such as safety cables or clamps can increase the risk of damage and or personal injury 5 Installation should only be performed by qualified and c...

Страница 6: ...r cord of this luminaire is damaged it shall be exclusively replaced by the manufacturer or his service agent or a similar qualified person in order to avoid a hazard 16 Please be aware that damages c...

Страница 7: ...d Female XLR Data Connectors Preprogrammed colored macros Strobe effect with a maximum flash rate of 18fps DMX controlled operation or stand alone operation with Master Slave function Individual contr...

Страница 8: ...cation please be sure that the fixture will not be exposed to extreme heat moisture or dust The minimum distance between the fixture and a wall or flat surface should be at least 5 meter about 1 5ft A...

Страница 9: ...embly Cool white warm white LED assembly 3 watt LEDS 2 Bracket Locking Knob This knob is used to secure the bracket in place after angle adjustments have been made 3 LED Housing This part include all...

Страница 10: ...t lock connector When jumping from fixture to fixture be sure to only use Elation IP rated power connectors to maintain the IP rating 7 Power Output Jack Use this jack to jump power to another ELAR DW...

Страница 11: ...yourself Improper installation can result in bodily injury Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet Mounting Th...

Страница 12: ...mp or be used in cluster allow multiple units to rigged together see the illustration below Regardless of the mounting option you choose please refer to the safety guidelines in this manual to avoid d...

Страница 13: ...below Be sure to only use properly rated DMX cables for DMX operation and not standrd audio cables If you are constructing your own cables be sure to use two conductor shielded digital cable rated at...

Страница 14: ...maximal stability when the input voltage is 100 120V only 8 devices may be connected together in this manner From the 9th devices please connect to power supply to get power for the second link when t...

Страница 15: ...ntrol signal This digital starting address is the channel number from which the fixture starts to listen to the digital control information sent out from the DMX controller The allocation of this star...

Страница 16: ...he display will show A XXX XXX representing the actual DMX address If the fixture is not receiving a DMX signal the display will flash A XXX XXX representing the actual DMX address If your fixture is...

Страница 17: ...indicator on the display This indicator is designed to give a quick visual indication of the fixtures DMX status The illustration below details the functionality of the LED indicators The LED indicato...

Страница 18: ...OCK ON OFF Key lock Press the MENU button for 3 seconds to activate CHAN 5CH 10CH DMX channel Mode FAIL OFF HOLD AUTO Status while there is no DMX DFSE ON OFF Default setting POHO ON OFF Preserves man...

Страница 19: ...internal power source that should last about five years VALU Display the DMX 512 value of each channel With this function you can display the DMX 512 value of each channel The display will automatica...

Страница 20: ...for better visualization when the fixture is mounted in an inverted position D ON The display is designed to turn off during normal operation to avoid excessive light in situations that require an ext...

Страница 21: ...output 2 HOLD which will hold the last DMX command or 3 AUTO which will put the fixture in sound active mode DFSE Restore Default This function is used to restore the factory settings of the device A...

Страница 22: ...ar Fixture Run Time This function resets the run time to zero 9 5 Edit Internal Program Settings The fixture comes equipped with a built in DMX recorder that allows custom programs to be installed and...

Страница 23: ...stands for Channel 11 of the editing scene the DMX value is XX 6 Adjust the DMX value by tapping the UP button until you get the expected effect for this channel 7 Press ENTER to enter the editing of...

Страница 24: ...1 by pressing the UP or DOWN buttons 3 Press MODE ESC the display shows SC01 4 Press MODE ESC the display shows C 01 5 Select CEDT by pressing the UP or DOWN buttons 6 Press MODE ESC the display shows...

Страница 25: ...Channel mode In this mode channel 1 controls all the cool white LEDs channel 2 controls all the warm white LEDs channel 3 controls the color_temperature channel 4 controls the strobe and channels 5 c...

Страница 26: ...No function shutter open Channel 5 dimming 0 255 Dimming 0 Black 255 100 10 Channel Mode This chart details a simple layout of the DMX channel assignment in CHANNEL 1 Cool white CHANNEL 2 Warm white C...

Страница 27: ...6 Warm White 0 255 Warm White group3 Channel 7 Cool White 0 255 Cool White group4 Channel 8 Warm White 0 255 Warm White group4 Channel 9 Strobe 1 95 Strobe effect slow to fast 96 127 No function shutt...

Страница 28: ...rial fatigue or sediments Never remove the ground prong from the power cable Further instructions depending on the installation spot and usage have to be adhered by a skilled installer and any safety...

Страница 29: ...with the product Elation Professional shall have no liability what so ever for loss of or damage to any such accessories nor for the safe return thereof C This warranty is void if the serial number ha...

Страница 30: ...ing warranties of merchantability or fitness are limited in duration to the warranty period set forth above And no warranties whether expressed or implied including warranties of merchantability or fi...

Страница 31: ...ELAR DW BRICK Elation Professional Los Angeles Ca 30 www ElationLighting com 13 PHOTOMETRIC DATA...

Страница 32: ...ELAR DW BRICK Elation Professional Los Angeles Ca 31 www ElationLighting com 14 DIMENSIONAL DRAWINGS...

Страница 33: ...ELAR DW BRICK Elation Professional Los Angeles Ca 32 www ElationLighting com 15 CHANGE LENS TO GET DIFFERENT BEAM ANGLES...

Страница 34: ...ELAR DW BRICK Elation Professional Los Angeles Ca 33 www ElationLighting com 16 CIRCUIT SCHEMATIC...

Страница 35: ...e Standard DMX 512 3 pole XLR Pin 3 Pin 2 Ground Pin 1 or Standard DMX 512 5 pole XLR n a Pin 5 n a Pin 4 Pin 3 Pin 2 Ground Pin Color Mixing Cool white and Warm white Color Additive Mixing Beam Angle...

Страница 36: ...Rev 01 06 2011 Version 1 3 Elation Professional 6122 S Eastern Ave Los Angeles CA 90040 323 582 3322 323 832 9142 fax www ElationLighting com Info ElationLighitng com...