4.2 Connection tab
The following settings are available:
Requested Packet Interval:
It is the measure of how frequently the originating application requires the
transmission of data from the target application. All values between 1 and 750 ms are accepted.
Connection over EtherNet/IP:
Unicast connections are point to point connections, while multicast
connections are considered one to many. Select unicast in order to reduce the amount of network
bandwidth used.
Inhibit Module:
When checked, the encoder is not polled for information any more. Any data provided will
be ignored by the controller.
Major Fault On Controller If Connection Fails While In Run Mode:
Check this box if a connection failure
should be considered a major fault.
Module Fault:
Fault messages will appear in this box.