VIA!4.0-EM/VIA!7.0-EM/VIA!10.0-EM E L A N H O M E S Y S T E M S
Page 32 © ELAN Home Systems 2007 • All rights reserved.
ELAN Z•System
Use a PVIA Wall Plate and a PZ6 Precision Panel for when installing VIA!s in
a Z•System. Connect IR, RS485+/-, GND, and +16VDC from the PVIA Wall
Plate to the VIA! Touch Panel as shown. Connect IR, RS485+/-, and GND
between the PVIA Wall Plate and the PZ6, as shown. Multiple VIA!s will con-
nect in the same way. Please consult the Z•630 Installation Manual for addi-
tional details.
Blue
White/Blue
Orange
White/Orange
White/Green
Brown
White/Brown
ELAN
C45P
+16V
GND
+16V
GND
V485+
V485-
IR
ST/SNS
Z485+
Z485-
SIR
Green
N/C
PVIA1 Rear
GND
P & DB
Zone 1 Shown
PZ6 Rear
Figure 3.21: Z•System Connections
Use
BOTH
Twisted
Pairs For Power
(GR,GR/WH & BR, BR/WH)
BLUE
WHITE/BLUE
ORANGE
WHITE/ORANGE
GREEN
WHITE/GREEN
BROWN
WHITE/BROWN
1
2
3
4
5
6
7
8
P
I
N # COLOR COD
E
FRONT
CABLE
Standard ELAN RJ-45 Pin-Out