© ELAN Home Systems 2007 • All rights reserved. Page 33
E L A N H O M E S Y S T E M S VIA!4.0-EM/VIA!7.0-EM/VIA!10.0-EM
Increasing Wire Runs Beyond the 200 Foot Maximum
If a VIA! Touch Panel must be mounted further than 200 feet from the head
end, it is possible to use a PVIA Wall Plate (typically a PVIA1) to power the
unit locally (within 110 feet). The diagrams in this section show specific wir-
ing schemes for Stand-Alone systems and each ELAN Multi-Room System.
Alternatively, a 2-conductor, 18AWG wire may be used to connect to the
External Power Port for wire runs longer than 200 feet. Please see
Using the
External Power Connector
on p. 35 for details.
Stand-Alone
Use local PVIA1s for connecting VIA!s to an amplified IR Connection Block
to make a large Stand-Alone system, as shown in
Figure 3.23
.
Blue
White/Blue
Orange
White/Orange
White/Green
Brown
White/Brown
ELAN
C45P
+16V
GND
+16V
GND
V485+
V485-
IR
ST/SNS
Z485+
Z485-
S
IR
Green
N/C
N/C
N/C
Blue
White/Blue
Orange
White/Orange
White/Green
Brown
White/Brown
ELAN
C45P
+16V
GND
+16V
GND
V485+
V485-
IR
ST/SNS
Z485+
Z485-
S
IR
Green
<110 Feet
>200 Feet
N/C
N/C
N/C
Blue
White/Blue
Orange
White/Orange
White/Green
Brown
White/Brown
ELAN
C45P
+16V
GND
+16V
GND
V485+
V485-
IR
ST/SNS
Z485+
Z485-
S
IR
Green
<110 Feet
>200 Feet
N/C
N/C
N/C
Blue
White/Blue
Orange
White/Orange
White/Green
Brown
White/Brown
ELAN
C45P
+16V
GND
+16V
GND
V485+
V485-
IR
ST/SNS
Z485+
Z485-
S
IR
Green
N/C
N/C
N/C
Amplified IR
Connection
Block
IR IN
GND
PWR1
PWR1
PWR1
PWR1
PVIA1 Rear
PVIA1 Rear
PVIA1 Rear
PVIA1 Rear
Figure 3.22: Stand-Alone Connections > 200'