El-Björn A 75F/R Скачать руководство пользователя страница 12

EN

12

SERVICE

MAINTENANCE

Once a year

Check the following points once a year.

The points must be checked by authorised staff  members.

• 

Cleaning of  evaporator.

• 

Cleaning of  drip tray and outlet.

•  Inspection of  all screwed joints.

• 

Inspection of  cooling and leak testing.

• 

Electrical inspection.

Perform the following measures when necessary:

•  Replace filter cassette 1–2 times per year.

•  Wash the fins of  the evaporator with dishwashing liquid and water as necessary.

Replacing the filter

1. 

Remove the upper screws on the filter hatch. Hinge down the hatch.

2. 

Pull out the filter cassette. Insert the new filter cassette. 

 

The arrow on the filter cassette should point inwards into the machine.

3. 

Close the filter hatch and tighten the screws.

RESETTING OF OVERHEATING PROTECTION (GT1:2)

If  the heating coil stops working, it may be due to the overheating protection 

 

being triggered.

GT1:2 is located inside the front cover and is reset as follows:

1. 

Turn off  power by removing the plug from the wall socket, or by turning off  

 

the main (operation) switch.

2. 

Look for the cause of  the protection being triggered and fix the fault

.

3.  The cause may be an electrical fault or poor air circulation.

4. 

Remove the upper screws on the filter hatch. Hinge down the hatch. There 

 

is a reset button for the overheating protection inside the front panel of the  

electrical box. Depress the button.

5. 

Close the filter hatch and tighten the screws.

Repairs/spare parts.

In case of  extensive repairs, please contact your distributor.

NOTE! During the warranty period, always contact the distributor before 

performing a repair.

When ordering spare parts, always state:

• 

Type

• 

Manufacturing number

Information concerning type can be found on the upper row of  the drying room

 

dehumidifier’s type plate.

Information concerning manufacturing number can be found underneath the bar  

code on the drying room dehumidifier’s type plate.

WARNING!
Before performing any maintenance work on the drying room dehumidifier, the machine 
must be disconnected from the electrical supply. 
This is done by unplugging the connector from the power socket.
All maintenance on the electrical system must be performed by qualified electricians.
All maintenance on the cooling system must be performed by qualified cooling technicians.

GT1:2

Содержание A 75F/R

Страница 1: ...Manual A 75F R...

Страница 2: ...n gon varningsdekal p avfuktare A75F R blivit deformerad eller sliten skall en ny best llas och monteras fortast m jligt f r att s kerst lla st rsta m jliga s kerhet vid anv ndandet av avfuktare A75F...

Страница 3: ...kan best llas som tillbeh r Alternativt st lls aggregatet upp p ett golvstativ eller annat plant och stabilt underlag intill en v gg Justera de st llbara f tterna s att avfuktaren st r v gr tt D avfuk...

Страница 4: ...m2 Anslut timern mellan elmatning och avfuktaren Observera att denna timer beh ver nollanslutning N En arbetsbrytare b r monteras f re timern Externa fl ktar tillbeh r F r kad luftcirkulation kan en e...

Страница 5: ...hj lp av arbetsbrytaren TERMOSTAT GT1 1 Termostat GT1 1 styr v rmebatteriet och r inst llbar 0 9 motsvarar ca 0 50 C Termostaten r placerad innanf r filterluckan Lossa de vre skruvarna p filterluckan...

Страница 6: ...n ur v gguttaget eller sl ifr n arbetsbrytaren 2 Kontrollera varf r skyddet har l st ut och tg rda felet Orsaken kan vara elektriskt fel eller d lig luftcirkulation 3 Lossa de vre skruvarna p filterlu...

Страница 7: ...ande El kretsen GARANTI Standardavtalet NL09 g ller f r El Bj rn AB s leveranser och produkter Enligt dessa best mmelser ansvarar El Bj rn AB f r fel som visar sig inom ett r fr n leveransen F r fackm...

Страница 8: ...e A75F R dehumidifier are shown on this page If any of the warning signs on the A75F R dehumidifier are damaged or worn new signs must be ordered and attached as soon as possible to ensure maximum saf...

Страница 9: ...ernative the device can be placed on a floor console or another flat stable surface close to a wall Adjust the feet so that the dehumidifier is horizontal When the dehumidifier has been supplied toget...

Страница 10: ...1 5 mm2 min area Connect the timer between the electrical supply and the dehumidifier Note that this timer requires an N connection N A main switch should be installed in front of the timer External f...

Страница 11: ...3 Selector C to position C 4 Refit the cover and switch on the dehumidifier using the main operation switch THERMOSTAT GT1 1 Thermostat GT1 1 controls the heating coil and is adjustable from 0 to 9 c...

Страница 12: ...ch 2 Look for the cause of the protection being triggered and fix the fault 3 The cause may be an electrical fault or poor air circulation 4 Remove the upper screws on the filter hatch Hinge down the...

Страница 13: ...rules WARRANTY El Bj rn AB s products and deliveries are regulated by Standard Agreement NL09 According to this Agreement El Bj rn AB is liable for faults arising within one year after delivery The p...

Страница 14: ......

Страница 15: ......

Страница 16: ...El Bj rn AB Box 29 334 21 Anderstorp Tel 0371 588 100 Fax 0371 181 34 info elbjorn se www elbjorn com KL597014 SE 131210...

Отзывы: