EN
12
SERVICE
MAINTENANCE
Once a year
Check the following points once a year.
The points must be checked by authorised staff members.
•
Cleaning of evaporator.
•
Cleaning of drip tray and outlet.
• Inspection of all screwed joints.
•
Inspection of cooling and leak testing.
•
Electrical inspection.
Perform the following measures when necessary:
• Replace filter cassette 1–2 times per year.
• Wash the fins of the evaporator with dishwashing liquid and water as necessary.
Replacing the filter
1.
Remove the upper screws on the filter hatch. Hinge down the hatch.
2.
Pull out the filter cassette. Insert the new filter cassette.
The arrow on the filter cassette should point inwards into the machine.
3.
Close the filter hatch and tighten the screws.
RESETTING OF OVERHEATING PROTECTION (GT1:2)
If the heating coil stops working, it may be due to the overheating protection
being triggered.
GT1:2 is located inside the front cover and is reset as follows:
1.
Turn off power by removing the plug from the wall socket, or by turning off
the main (operation) switch.
2.
Look for the cause of the protection being triggered and fix the fault
.
3. The cause may be an electrical fault or poor air circulation.
4.
Remove the upper screws on the filter hatch. Hinge down the hatch. There
is a reset button for the overheating protection inside the front panel of the
electrical box. Depress the button.
5.
Close the filter hatch and tighten the screws.
Repairs/spare parts.
In case of extensive repairs, please contact your distributor.
NOTE! During the warranty period, always contact the distributor before
performing a repair.
When ordering spare parts, always state:
•
Type
•
Manufacturing number
Information concerning type can be found on the upper row of the drying room
dehumidifier’s type plate.
Information concerning manufacturing number can be found underneath the bar
code on the drying room dehumidifier’s type plate.
WARNING!
Before performing any maintenance work on the drying room dehumidifier, the machine
must be disconnected from the electrical supply.
This is done by unplugging the connector from the power socket.
All maintenance on the electrical system must be performed by qualified electricians.
All maintenance on the cooling system must be performed by qualified cooling technicians.
GT1:2