13. SWITCHING THE COMPRESSOR ON
(Fig.7)
Compressor switch on at pressure switch by turning the shift (3) to position
“I” , compressor starts to work and pressurize air to air chamber. At the
compressed air consumption the pressure in the air nozzle drops to the
closing pressure, the compressor in put into operation and the air nozzle is
filled with compressed air. After reaching the cutoff pressure the
compressor turns off automatically. After releasing – pressure decreasing in
the air nozzle and reaching the closing pressure, the compressor is again
put into operation. Check this value at manometer (5). Setting of switching
or switching-off pressure can vary within the range of i
±
10%. Air pressure
in air chamber must not exceed maximal permitted operation pressure.
It is not allowed to tamper and change pressure limits of pressure switch at compressor
Pressure switch (2) was adjusted by manufacturer
MAINTENANCE
14. MAINTENANCE INTERVAL
Maintenance that must be performed
Chapter
Time interval
Performed by
• Release condensate
Compressor without air drier
At high air humidity
Compressors with air drier
Compressors with condensation unit :
- from filter
- from pressure vessel
15.1
1 x week
1 x day
1 x week, control the function
1 x week, control the function
1 x week
operating staff
operating staff
operating staff
operating staff
operating staff
• Control safety valve
15.2
1 x year
qualified expert
• Replacement of input filter
15.3
1 x of 2 years
qualified expert
• Replacement of filter and checking
of the filling in drier
15.4
1 x year
qualified expert
• Replacement of filter
in condensation unit
15.5
1 x year
qualified expert
• Control of tightness of joints and
control examination of device
Service
documentation
1 x year
qualified expert
15. MAINTENANCE
Repair works that exceed the framework of common maintenance can be performed only
by qualified expert or customer service of manufacturer.
Use only spare parts and accessories prescribed by manufacturer.
Prior every work at maintenance or repair, switch off the compressor and disconnect it
from mains (pull out mains plug).
In order to find out correct work of compressor, it is necessary, in certain intervals (Chapter 14) to perform
the following activities:
15.1. Condensate drain down
Compressors
(Fig.8)
In the case of regular operation, it is recommended to release condensate
from pressure tank 1 x week (at high air humidity 1 x day).
•
Switch off the compressor from mains and reduce air pressure in the
device to pressure of max. 1 bar, for example by releasing air via
connected device.
•
Canalize hose with sludging valve to vessel prepared in advance. By
opening the release valve (1) release condensate from tank.
•
Wait till condensate is fully delivered from pressure tank.
•
Again close release valve (1).
Fig.7
3
5
2
1
4
Fig.8
1
Содержание DK50 S
Страница 2: ......
Страница 3: ...DK 50 06 2008 3 NP DK50_2 OBSAH 4 CONTENTS 18 32 INHALT 47 SOMMAIRE 61 SPIS TRE CI 76 Ed 2 F...
Страница 33: ...DK50 06 2008 33 NP DK50_2 1 CE CE 93 42 EEC 2 2 1 2 2 2 3...
Страница 34: ...DK50 NP DK50_2 34 06 2008 3 CE 4...
Страница 37: ...DK50 06 2008 37 NP DK50_2 14 2 19 8 3 MONZUN M1 10 19 2 21 0 I 8 I 0 4 A a 1 8 3 2 10 11 12 40 C 32 C...
Страница 38: ...DK50 NP DK50_2 38 06 2008 1 2 MONZUN M1 10 1 A a 2 3 4 5 6 7 8 9 o 10 11 12 13 14 15 16 17 18 19 20 21 a a...
Страница 39: ...DK50 06 2008 39 NP DK50_2 3 MONZUN M1 10 4 KJF1...
Страница 40: ...DK50 NP DK50_2 40 06 2008 9 5 C 40 C 70 6 10 10 1 5 X Y...
Страница 45: ...DK50 06 2008 45 NP DK50_2 15 5 11 1 1 2 3 16 10 1 8 3 2 7 17 1 8 18 11...
Страница 46: ...DK50 NP DK50_2 46 06 2008 19...
Страница 95: ......