DK50
NP-DK50_2
- 28 -
06/2008
PE
N
U
E V1
EV2
YV 1
C
40°C
N
U
X1
FU
1
2
3
X2
4
PE
2
1
3
S P
p >
ST
M
Z2
Z1
U2
150°C
U 1
1/N/PE ~ 230 V 50..60 Hz
ELECTRIC OBJECT O F 1st CAT.
B TYPE
D K50-10Z/M , D K50-10S/M
P E
N
U
EV1
YV 1
EV2
B1
C
B2
C
N
U
X1
FU
1
2
3
40°C
ELECTRIC O BJECT O F 1st CAT.
1/N/PE ~ 115 V 60 Hz
B TYPE
S P
p >
ST
X2
4
PE
2
1
3
M
Z2
Z1
U 2
150°C
U 1
D K50-10Z/M , D K50-10S/M
ST Therm o switch YV1 Solenoid valve
SP Pressure sw itch Cb1, Cb2 Capacitor
M M otor of com pressor FU Fuses,T16A
EV1 Fan of com pressor X1, X2 Term inal
EV2 Fan of dryer
ST Therm o sw itch YV1 Solenoid valve
SP Pressure sw itch Cb1 Capacitor
M M otor of com pressor FU Fuses,T10A
EV1 Fan of com pressor X1, X2 Term inal
EV2 Fan of dryer
12. FIRST PUTTING INTO OPERATION
(Fig.7)
•
Check whether all fixation elements used during transport were removed.
•
Check due connection of pressurized air lines.
•
Check due connection to mains.
•
Start compressor at pressure switch (2) by turning switch (3) to position „I“.
Compressor
– at first putting into operation, air chamber is pressurized to switching-off pressure and
compressor is automatically switched off. Later compressor works in automatic mode, according to the
consumption of pressurized air the compressor is either switched on or off by pressure switch.
Compressor with dryer
– the appliance during its operation also takes out humidity from pressure tank via
air dryer and blows out via outlet at air dryer, this can be heard as noise of blowing out.
Compressor with condensation and filtration unit
– during operation KJF-1 filters air, captures humidity
and automatically releases condensed liquid through the filter´s discharge valve.
Compressor is without emergency power supply .
OPERATING
In the case of danger, compressor disconnect from mains (pull out mains plug).
Compressor aggregate has hot surfaces.
There is a danger of scorching while contacting them.
During longer operation of compressor, temperature in box is increased over 40°C and
then cooling ventilator is automatically switched on. After cooling of the space under ca
32°C, ventilator is again switched off.
Automatic start. If pressure in pressure tank drops to switching pressure, compressor is
automatically switched on.
The compressor automatically switches off when the pressure
in the air nozzle reaches the cutoff pressure.
Содержание DK50 S
Страница 2: ......
Страница 3: ...DK 50 06 2008 3 NP DK50_2 OBSAH 4 CONTENTS 18 32 INHALT 47 SOMMAIRE 61 SPIS TRE CI 76 Ed 2 F...
Страница 33: ...DK50 06 2008 33 NP DK50_2 1 CE CE 93 42 EEC 2 2 1 2 2 2 3...
Страница 34: ...DK50 NP DK50_2 34 06 2008 3 CE 4...
Страница 37: ...DK50 06 2008 37 NP DK50_2 14 2 19 8 3 MONZUN M1 10 19 2 21 0 I 8 I 0 4 A a 1 8 3 2 10 11 12 40 C 32 C...
Страница 38: ...DK50 NP DK50_2 38 06 2008 1 2 MONZUN M1 10 1 A a 2 3 4 5 6 7 8 9 o 10 11 12 13 14 15 16 17 18 19 20 21 a a...
Страница 39: ...DK50 06 2008 39 NP DK50_2 3 MONZUN M1 10 4 KJF1...
Страница 40: ...DK50 NP DK50_2 40 06 2008 9 5 C 40 C 70 6 10 10 1 5 X Y...
Страница 45: ...DK50 06 2008 45 NP DK50_2 15 5 11 1 1 2 3 16 10 1 8 3 2 7 17 1 8 18 11...
Страница 46: ...DK50 NP DK50_2 46 06 2008 19...
Страница 95: ......