Air outlet
Cooling air inlet
Recommended flow
of cooling air:
DK50 9x4VRT/M – 3250
m3/h
Applies for continuous
operation and cooling air
temperature of 20°C
Space conditions
- Tempe5°C
÷
+40°C
- - Relative humidity 70%
Fig.4
INSTALLATION
11. CONDITIONS FOR USE
The compressor may only be installed and
operated in dry, well-ventilated and dust-free
areas.
The compressor must be installed so that it is
accessible at all times for operating and
maintenance. Please ensure that the
nameplate on the device is readily accessible.
The compressor must stand on a flat,
sufficiently stable base (be aware of the
weight of the compressor, see Technical
Data).
The compressor on the operator’s side must
be at least 70 cm from the wall to allow air
flow for cooling purposes and to ensure the
safety of the operator and maintenance
personnel.
Operating the equipment in areas in
which flammable mixtures may be
present, such as in operating rooms,
coal storage areas, etc., is prohibited.
Flammable
materials
pose
an
explosion hazard.
Ensure power cords and air hoses
are not damaged. The power cord
may not show signs of stress and
must be kept without tension (putting
any objects on it is prohibited) and
subjecting the cord to external heat in
any form is prohibited.
Environmental requirements:
Temperature :
+5°C to +40°C,
Max. relative humidity:
70%,
Max. absolute humidity:
15 g/m
3
.
Approximately 70% of the electrical energy
used by the compressor air pumps is
converted to heat and therefore the rooms in
which a compressor assembly is installed
must have additional ventilation to provide
sufficient air exchange for cooling purposes
(see the technical data)
Caution! Hot surface!
Portions of
the compressor may be hot and
reach hazardous temperatures during
compressor operations that may
harm materials or operating staff.
Fire hazard!
Содержание DK50 9x4VRT/M
Страница 1: ...DK50 9x4VRT M User manual EN...
Страница 2: ...October 2018 Z_2195 2018 Chap 3 pgs 5...
Страница 22: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 22 10 2018 Fig 13 Fig 14 Fig 15 Cable bridge...
Страница 42: ...DK50 9x4VRT M NP DK50 9x4VRTM_ED EN 2_10 2018 42 10 2018 ANNEX 22 MAPPING PARAMETERS...
Страница 43: ...DK50 9x4VRT M 10 2018 NP DK50 9x4VRTM_ED EN 2_10 2018 43...