background image

FUEL BED LAYOUT 
(continued)

3. Locate the two front coal sections
marked ‘L’ and ‘R’  into the slot along the
front of the burner tray as shown. The legs
of the coals have a slightly tapered front
face which is intended to give a tight inter-
ference fit into the tray.

Do not alter the slot in the tray front, so
that the coals become a loose fit.

4. Open the bag of 16 moulded coals.
All of the coals are the same. Take six
coals and place them as shown. Care
should be taken to ensure that the
coals bridge the gap between the front
coal and the four coal supports at the
front of the matrix. 

5. Take five more moulded coals and posi-
tion as shown along the rear of the matrix.
Do not place the coals directly over the
holes in the matrix. The coals may be rotat-
ed as desired to ensure they sit firmly on
the various  supporting parts of the matrix.

6. Finally, take the five remaining coals
and position as shown. These coals
should rest on the front and rear rows
of coals, rather than sitting directly on
the matrix. Adding these coals should
complete the appearance of the fuel
bed giving an even distribution of
equally spaced coals.

The fire is designed to operate correctly with the sixteen coals supplied when assembled accord-
ing to the instructions. Never add to the sixteen coals, or change them for a different type. Never
throw rubbish or other matter onto the fuel bed. Please note: some discolouration/sooting is to be
expected during normal use.

3

5.0

R

L

©

2009 Focal Point Fires plc.

Содержание EKO 3070

Страница 1: ...installation and user instructions All instructions must be handed to user for safekeeping Revision A 06 09 Country s of destination GB IE eko 3070 fuel effect gas fire...

Страница 2: ...ly used in a sufficiently venti lated space The appliance is designed for installation on to a non combustible hearth of at least 300mm depth This appliance is factory set for operation on the gas typ...

Страница 3: ...fractories and coal bed are constructed from ceramic fibre 1 Section 1 0 2 0 3 0 4 0 4 1 5 0 6 0 7 0 7 1 8 0 8 1 9 0 10 0 Contents Important Notes Appliance Data Installation Requirements Site Require...

Страница 4: ...e checked before installation by using a smoke pellet or similar to ensure proper draw and that leakage is not evident at any joints Repair and re test as necessary before the appliance is installed T...

Страница 5: ...erly up the flue the outlet at the back of the appli ance must have a 50mm minimum clearance between it and the back wall of the opening or any other obstruction The area immediately above the outlet...

Страница 6: ...BOXES This appliance can be fitted into a number of proprietary flue boxes provided that the minimum dimensions given in the diagram below are complied with Constructional Note The frame of the fire a...

Страница 7: ...de panels should be fitted by inserting their front edges into the pre fitted retaining brackets on the front face of the fire box Gently align the side panels with the side of the firebox as shown ov...

Страница 8: ...ectly the sealing face sits flat and square to the wall or infill panel and that the base is firm on the floor of the opening as no leaks are permissible here At this stage it is essential to ensure t...

Страница 9: ...ion does not allow the exact layout given the eyebolts should be positioned as close to the correct layout as possible Before finally fitting cables ensure the self adhesive sealing strips are in posi...

Страница 10: ...adjust this If under any circumstances the electric spark fails the pilot may be lit manually by proceeding with the ignition sequence as previously described and after turning the control knob throug...

Страница 11: ...cleaning of the fire may be achieved when the fire is cold using a damp cloth and mild detergent on most surfaces Scratched and other superficial damage to the matt black paintwork of the appliance ca...

Страница 12: ...any debris Remove the two tubing nuts on the ends of the gas pipe to the injector elbow and blow clear Release the screw through the supporting leg and lift assembly clear The injector pipe can now b...

Страница 13: ...and then cuts off Excessive room draught or flue pull rectify Loose or faulty thermocouple rectify ODS system in operation Firebox grommet seal not fitted rectify Lint in pilot aeration hole clean th...

Страница 14: ...ial or flooring should protrude onto the hearth DO NOT burn any foreign material on this fire the coals must be of the correct type and laid out in accor dance with the relevant section of these instr...

Страница 15: ...d ventilation of at least 8 75cm2 The requirements of other appliances operating in the same space or room and the results of a spillage test must be taken into con sideration when assessing ventilati...

Страница 16: ...ong the rear of the matrix Do not place the coals directly over the holes in the matrix The coals may be rotat ed as desired to ensure they sit firmly on the various supporting parts of the matrix 6 F...

Страница 17: ...ught should resolve this The fire can then be re lit in accordance with the previous section A grommet seal may also be missing from the firebox causing abnormal draught to shut down the pilot Call yo...

Отзывы: