When the device is installed in place, make sure that the 

shield is in the correct position according to the required 

area masking.

Installation

At this point it is recommended to carry out the commis

-

sioning of the device (see “Commissioning”), or at least 

the download of the physical address, using the program-

ming button placed close to the bus connector; alternati-

vely, programming mode can be activated later when the 

device is already installed by means of the EK-QR6-IR 

remote controller. Fix the sensor body to the base pla-

te securely through its own mounting screws and finally 

adjust the position of the sensor head.

Section of shield applied

Active range (h = 2.5m)

Angular section

-8.5° per section

A + B 

Ø 10 m

A

Ø 14 m

None

Ø 32 m

Warning!

 

The electrical connection of the device 

can be carried out only by qualified personnel. The 

incorrect  installation  may  result  in  electric  shock 

or  fire.  Before  making  the  electrical  connections, 

make sure the power supply has been turned off.

Warning!

 

In  order  to  supply  the  KNX  bus  lines 

use only KNX bus power supplies (e.g. ekinex EK-

AB1- TP or EK-AG1-TP). The use of other power 

supplies can compromise the communication and 

damage the devices connected to the bus.

Warning!

 

The sensor is a low voltage circuit; ne-

ver connect it with the 230V line network. Do not 

run  the  KNX  wiring  in  the  same  conduit  used  by 

line network wiring.

In order to apply the shield, first remove the decorative 

bezel from the body. Insert the clip of the shield section on 

the edge of the bezel, so that it extends below. Reapply 

the bezel making the shield cover part of the lens; the 

bezel secures the shield edge against the body.

The device has degree of protection IP55 (Wall mount) / 

IP54 (Ceiling mount), and is therefore suitable for use in 

an outdoor environment. During the fixing of the base pla

-

te, until the wiring is connected and possibly the sensor 

is tested for accuracy and correct positioning, the device 

can be temporarily mounted by locking it on the baseplate 

through a plastic hook. Once all adjustments have been 

made, the sensor can be eventually mounted on the base 

plate. For application on inner or outer corners, a corner 

mounting support is available as an accessory.

Installation procedure - Standard mount

Apply the device body to the base plate by means of the 

support hook:

Mount the base plate on the wall / ceiling in the desired 

position by means of the supplied screw anchors. Drive 

the incoming bus cable through the rubber perforation ca-

ble guides and connect the device.

The sensor head  can be adjusted  up to 40° downward 

and 90° upward, and rotated horizontally max. 90° in ei-

ther direction.