Maintenance and repair
20
FM074342
2015-10-09·BA00·III·en·04
Portable Lamp
HSE 7 LED / LS 7 LED
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
• Remove the screws (1) at the head.
• Remove lamp head from the enclosure.
• Pull the connection lines (A1, A2) off the charging contacts (B1, B2).
• Pull the connection lines (2) off the battery contacts.
• Remove the screws (3) from the retaining bracket.
• Remove the battery retaining bracket (4).
• Remove battery (5) from the enclosure.
• Insert new battery into enclosure according to marking.
• Insert battery retaining bracket (4).
• Screw down the battery retaining bracket with the screws (3) -
tightening torque 0.5 Nm.
• Connect the red connection line "+" (2) to the battery contact marked in red "+".
• Connect the blue connection line "-" (2) to the battery contact marked in blue "-".
• Connect the connection line (A1) to the charging contact (B1).
• Connect the connection line (A2) to the charging contact (B2).
• Place the lamp head on the enclosure.
• Fasten the lamp head to the enclosure with the screws (1) -
tightening torque 0.5 Nm.
• Insert portable lamp briefly into charging unit.
10.1.2 Cleaning
• Clean the device only with a damp cloth.
• Use water or mild cleaning agents.
• Do not use abrasive, scratching and aggressive detergents or solvents.
15005E00
1 6 screws for head (Torx 10)
A1 PCB connection line
2 PCB connection line (+; -)
A2 PCB connection line
3 2 screws for retaining bracket (Torx 10) B1 Charging contact connection line
4 Battery retaining bracket
B2 Charging contact connection line
5 Battery
NOTICE
Wrong connection of the connection lines will damage the portable lamp.