PD120 OWNERS MANUAL 

Drawing No.  :-  TPC368 
Issue 

:-  6 

Date 

:-  07/09/18 

 

SPECIFICATIONS 

    
    

 

 

 

M

M

M

M

ODEL

ODEL

ODEL

ODEL

::::    

Ebac PD120 

H

H

H

H

EIGHT

EIGHT

EIGHT

EIGHT

::::    

441m 

W

W

W

W

IDTH

IDTH

IDTH

IDTH

::::    

683mm 

D

D

D

D

EPTH

EPTH

EPTH

EPTH

::::    

658mm 

W

W

W

W

EIGHT

EIGHT

EIGHT

EIGHT

::::    

70.5Kg 

A

A

A

A

IR

IR

IR

IRFLOW

FLOW

FLOW

FLOW

::::    

Low 450 M

3

/hr 

High 850 M

3

/hr 

H

H

H

H

ORSEPOWER

ORSEPOWER

ORSEPOWER

ORSEPOWER

::::    

1.5 

P

P

P

P

OWER 

OWER 

OWER 

OWER 

S

S

S

S

UPPLY

UPPLY

UPPLY

UPPLY

::::    

230V / 50Hz / 1ph 

F

F

F

F

INISH

INISH

INISH

INISH

::::    

Powder-coated Epoxy 

R

R

R

R

EFRIGERANT 

EFRIGERANT 

EFRIGERANT 

EFRIGERANT 

T

T

T

T

YPE

YPE

YPE

YPE

/Q

/Q

/Q

/Q

TY

TY

TY

TY

::::    

R407c 

Содержание 1028225

Страница 1: ...PD120 OWNERS MANUAL Drawing No TPC368 Issue 6 Date 07 09 18 EBAC MODEL PD120 INDUSTRIAL DEHUMIDIFIER OWNER S MANUAL www eipl co uk...

Страница 2: ...s the moist air through the cold evaporator coil which cools the air below its dew point Moisture forms on the evaporator coil and is collected in the condensate tray which is equipped with a permanen...

Страница 3: ...TH EPTH EPTH 658mm W W W WEIGHT EIGHT EIGHT EIGHT 70 5Kg A A A AIR IR IR IRFLOW FLOW FLOW FLOW Low 450 M3 hr High 850 M3 hr H H H HORSEPOWER ORSEPOWER ORSEPOWER ORSEPOWER 1 5 P P P POWER OWER OWER OWE...

Страница 4: ...unit inlet and outlet must have a clearance of 0 5M from all adjacent surfaces and or structures Before connecting this unit to the relevant power supply the following must be carried out Selecting t...

Страница 5: ...running for 15 minutes E Observe the evaporator coils behind the filter on the air inlet end of the unit to confirm frost formation i If the air temperature is below 70 F an even coating of frost shou...

Страница 6: ...the fins Alternatively vacuum clean the coils WARNING DO NOT STEAM CLEAN REFRIGERATION COILS 2 Check that the fan is firmly secured to the motor shaft and that the fan rotates freely The fan motor is...

Страница 7: ...of the refrigerant compressor The charging stub should be crimped and rebrazed after servicing NEVER allow permanent service valves to be fitted to any part of the circuit Service valves may leak cau...

Страница 8: ...on 4 Check the wiring diagram to find fault and repair Little or no water extraction 1 Insufficient air flow 2 Compressor fault 3 Loss of refrigerant gas 1 Check all of the above 2 Contact the Factory...

Страница 9: ...azard This product contains fluorinated greenhouse gases covered by the Kyoto Protocol The refrigeration system is hermetically sealed The Global Warming Potential GWP of refrigerants used in products...

Страница 10: ...90 www eipl co uk sales eipl co uk American Sales Office Ebac Industrial Products Inc 700 Thimble Shoals Blvd Suite 109 Newport News Virginia 23606 2575 USA Tel 01 757 873 6800 Fax 01 757 873 3632 www...

Отзывы: