Drawing : - TPC390
Issue
: - 5
Date
: - 17/01/17
INTRODUCTION
Designed for a wide range of applications, the ECO85 dehumidifier is a
rugged, industrial unit which utilizes an energy-efficient compressor and a
compact portable design to provide easy efficient drying.
The ECO85 has a number of special features:
•
Compact Size
•
High efficiency rotary compressor
•
Ebac’s
“Hot Gas”
defrost system
•
Exterior epoxy powder-coated finish
•
Provision for permanent drainage
•
Extra long power cord
The fan draws the moist air through the cold evaporator coil, which cools the
air below its dew point. Moisture forms on the evaporator coil and is collected
in the condensate tray, which is equipped with a permanent drain. The cooled
air then passes through the hot condenser coil where it is reheated using the
same energy removed during the cooling phase, plus the additional heat
generated by the compressor. The air is, therefore, discharged from the
dehumidifier at a slightly higher temperature with a lower absolute humidity
than that which entered. Continuous circulation of air through the
dehumidifier gradually reduces the relative humidity within the area.
The ECO85 dehumidifier is a rugged, reliable drying unit designed to operate
effectively over a broad range of temperature and humidity conditions. An
active hot gas defrost system, controlled by an electronic timer, guarantees
positive de-icing, thereby optimizing operation at low temperatures.
The unit incorporates a welded and galvanized steel chassis and is finished in
an epoxy coating for resilience to damage caused by rough handling.
The dehumidifier unit is fitted with a transformer which will allow the unit to
operate on either 110volts or 230volts 1ph 50Hz power supply.
All electrical components within the dehumidifier are rated for 110volts, for
safety reasons. The voltage change over (selector switch) switch, can be
found mounted to the back of the electrical panel accessed via the outlet
panel.