Eilon Engineering Ltd. RON 2501 NG Operating Manual
8
The RON 2501 is available calibrated in lbs, kgs, metric tons, short tons, newtons,
deca-newtons or kilo newtons.
RON 2501 options include:
1)
*
Digital RS-232 output for communication with computer, printers etc.
user-selectable; continuous data flow or print on demand.
2)
*
User-selectable baud rate.
3)
*
User-adjustable set points.
4)
*
User-selectable units.
5)
*
Additional remote wireless display/s, similar to the main one.
6)
*
Additional remote display 2" (50mm) LCD with cable.
7)
*
Totalizer, for totaling up accumulated loads.
8)
*
Data logging: stores data and time, up to 600 load measurements, with print
capability.
9)
*
Data logger with extended memory capacity for storing up to 3000 load
measurements.
10)
*
Rechargeable batteries (instead of disposable) and a charger to charge the
batteries inside the system.
11)
*
Specially fitted carrying case.
12)
*
High accuracy 0.05% of full range + 1 resolution step and imported
resolution (50% of standard).
13)
*
Indicator belt clip (for hanging the indicator on a belt).
14)
*
Heat shield for hot industries.
15)
*
Clock – real time clock.
2.
BATTERY CARE AND MAINTENANCE
The standard system is equipped with disposable 1.5V (“finger”) type Alkaline
batteries fixed in special battery racks. The load cell contains 4 and the indicator 3.
The battery rack is located in the lower part of the indicator.
To replace batteries, press the two small latches on both sides of the lower part of
the indicator. The battery rack is just behind the lower indicator box cover that is
released by the two latches.
The load cell batteries can be replaced by opening the four Philips screws securing
the body cover – the one without the antenna.
Use high quality, high energy Alkaline 1.5V AA size batteries.