Eilon Engineering Ltd. RON 2501 NG Operating Manual
10
3. OPERATION
To operate the system, press the load cell ON/OFF key until the red “power” LED
illuminates. Keep the key depressed for a second or two after it illuminates. The red
light should flash at approx. 5 second intervals. Check that it lights again. Turn the
indicator on by pressing the ON/OFF key until you hear the bleep and the display
shows the units in use – Lbs, Kgs, or other. This indicates the measuring value. A
short TR.ERR (Transmission Error) sign may appear in between. The receiver
indicator synchronizes itself to its paired transmitter (load cell). If it does not
succeed, the TR.ERR sign will be displayed. If this sign remains for several
seconds, an “ESC” sign will replace the TR.ERR.
Press the ESC key. If there is one row of keys on your indicator, the escape key is
not visible. You will find it indicated above the MAX. key. Pressing the ESC key
initiates the indicator. It will attempt to receive its paired load cell transmissions. If
it succeeds, the indicator will start showing measurements. If it does not, it will
show TR. ERR for several seconds and then “ESC” again.
Check if the load cell (red) power led flashes (about once every 5 seconds). If it
does not, try to start it by pressing the ON/OFF key and repeat the above-
mentioned procedure.
If the problem was not solved in the above procedure, switch off the load cell and
the indicator and return the complete system for repair.
The available units in this system are:
M. TON = Metric Tons
S. TON = Short Tons = “American” tons = 2000 Lbs
Lbs
Lbs x 10
K.NTON = Kilo Newton
DECA.N = Deca Newton
N.WTON = Newton
KG
Before loading the unit, press the “ZERO” key until the word “zero” is displayed.
The zero value will be displayed after a few seconds.
Please check that the indicator is in the “off” position after use.