-46-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range
Note
5 APL Threshold Min
4/4
0-255
(AV/PC)
6 APL Threshold Max
9/9
0-255
(AV/PC)
10 Close Limit Dimmer 0
728
0-1023
11 Close Limit Dimmer 1
714
0-1023
12 Close Limit Dimmer 2
684
0-1023
13 Close Limit Dimmer 3
654
0-1023
14 Close Limit Dimmer 4
624
0-1023
15 Close Limit Dimmer 5
594
0-1023
16 Close Limit Dimmer 6
564
0-1023
17 Close Limit Dimmer 7
534
0-1023
18 Close Limit Dimmer 8
504
0-1023
19 Close Limit Dimmer 9
474
0-1023
20 Close Limit Dimmer 10
444
0-1023
21 Close Limit Dimmer 11
414
0-1023
22 Close Limit Dimmer 12
384
0-1023
23 Close Limit Dimmer 13
354
0-1023
24 Close Limit Dimmer 14
324
0-1023
25 Close Limit Dimmer 15
294
0-1023
30 Update Interval
18/18
0-1023
(AV/PC)
Group
230
VBI Slice Level
0 Generic Initial Slicing Level
PW190 register 0xE344
9
0-255
1 Generic High Level Threshold PW190 register 0xE345
0
0-255
2 Generic Low Level Threshold PW190 register 0xE346
0
0-255
3 Generic Minimum Low Level PW190 register 0xE347
0
0-255
4 Generic Maximum High Level PW190 register 0xE348
255
0-255
Group
250
FAN control
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
38
0 - 255
1 FAN1 MAX ADJUST (DAC)
233
0 - 255
2 FAN2 MIN ADJUST (DAC)
38
0 - 255
3 FAN2 MAX ADJUST (DAC)
230
0 - 255
4 FAN3 MIN ADJUST (DAC)
31
0-255
5 FAN3 MAX ADJUST (DAC)
214
0-255
6 Not used
7 Not used
Group
252
FAN option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land, 2-4: Hi-Land
1-3
0
0 - 5
1 SAFETY SWITCH
For test purpose
0
0 - 6
2 FAN MANUAL SWITCH
0: Auto, 1: Manual
0
0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100
0 - 255
4 FAN2 MANUAL VOLTAGE
100
0 - 255
5 FAN3 MANUAL VOLTAGE
100
0 - 255
Group
253
Fan tem error Setting (Memorized)
Normal Ceiling
HiLand-Normal
HiLand-Ceiling
0 Temp A Warning (High)
45
51
47(On1),48(On2) 49(On1),50(On2)
-
1 Temp B Warning (High)
58
63
58
63
-
2 Temp C Warning (High)
63
68
63
68
-
3 Temp B-A Warning(High)
100
100
100
100
-
4 Temp C-A Warning(High)
100
100
100
100
-
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
45
50
46(On1),47(On2) 48(On1),49(On2)
30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
58
63
58
63
30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
63
68
63
68
30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
9 Temp C-A Warning(Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at Eco
(Room)
45
46
46
47(On1),48(On2)
30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
58
58
58
58
30-100
12 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
62
62
62
62
30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
Содержание LC-XBM31
Страница 20: ...20 Optical Parts Disassembly b Relay Out lens disassembly Relay Out lens Relay lens Ass y Fig 5 M 2 5x6...
Страница 66: ...66 IC Block Diagrams MAX232ECPWRP RS 232C Driver IC3801 L3E06200P0A D A S H LCD Driver IC501 IC531 IC561...
Страница 67: ...67 IC Block Diagrams PW190 Scaler IC301 MR4010 Power OSC IC631...
Страница 69: ...69 IC Block Diagrams TB6608FNG IRIS Control IC601 TLV320AIC3105 Audio Control IC5002...
Страница 74: ...74 Parts Location Diagrams KT8 XBM3100 S03 L05 Relay out M03 Relay lens Out assembly...
Страница 95: ...Key No Part No Description Key No Part No Description 95 Electrical Parts List KT8 XBM3100...
Страница 96: ...KT8BE November 2010 Printed in Japan 2010 Eiki Internatinal Inc A key to better communications...