2 installation instructions
Cable routing
WARNING
Electrical shock (230 V) resulting from dam-
age to cable
pass the cable through the cable holder to
guarantee electrical safety and the integrity
of the cable.
CautION
Danger of crushing/property damage from
incorrect cable placement
install the electromechanical module next to
the voltage supply inlet. note while doing so
that the mains cable proceeds outward from
the product on the window side!
Do not disconnect the mains cable in the
area between the drive and the red cable
marking!
cable holder
Wiring
WARNING
Electrical shock (230 V) resulting from dam-
age to cable
protect mains cable against contact with the
activated window shutter!
CautION
Impairment of the antenna and the radio
range
Do not alter the placement of the cables in
the interior of the product!
Do not cut off the cable in the interior of the
product!
always switch off the power supply via the
mains cable before each operation.
OFF
connect the drive as follows:
230 V
50 Hz
VOLETRONIC io
switch on the voltage supply.
ON
the Voletronic io folding shutter drive con-
firms by means of
an
audible signal
. if this is not
the case, check the electrical connection again.
switch off the power supply again after
checking the electrical connection.
OFF