background image

Voletronic io

Motorisation for window shutters

installation and
operating instructions

installation
specialist personnel
Valid from 03.2021

E 641.4

Содержание Voletronic io

Страница 1: ...Voletronic io Motorisation for window shutters Installation and operating instructions Installation specialist personnel Valid from 03 2021 E 641 4...

Страница 2: ...the commissioning of the EHRET VOLETRONIC io window shutter drive Remove the labels stuck to the shutters after installation These Installation and operating instructions are addressed to qualified s...

Страница 3: ...rails to the sash 19 Commissioning 20 Cutting the coupling rod to size and mounting it 24 Crimped metal ribbon 25 3 Operation Opening and closing 26 Preferred position my 26 Detecting obstacles and fr...

Страница 4: ...stallation instructions Warning Take into account the following notes and warnings in order to avoid dangers and to protect the product Observe the accident prevention regula tions of the Accident Pre...

Страница 5: ...ve reached their final position Do not reach into moving parts or closing areas while shutters are opening or closing Make sure that no articles of clothing or body parts are able to be caught by movi...

Страница 6: ...as with the following standards EN 60335 1 2012 A1 2019 A11 2014 A13 2017 A14 2019 A2 2019 EN 60335 2 97 2006 A11 2008 A12 2015 A2 2010 EN 62233 2008 EN 62479 2010 EN 301489 1 V2 2 3 2019 EN 301489 3...

Страница 7: ...coupling rod is cut to size and mounted in the case of multiple section sashes and if express hinges are used then these are secured Electrical installation Warning Electrical shock 230 V Notes The co...

Страница 8: ...you require information about collection points near you Recyclable materials of the machine Reusable material Components Aluminium Shutters Drive housing Coupling Guide rail Fittings Copper Cables Mo...

Страница 9: ...e system for a max of 2 sashes per side for the electronic actuati on of window shutters The drive is equipped with tri band bidirec tional io homecontrol and is suitable for all types of window shutt...

Страница 10: ...sash M3 6 mm S1 1 1L 1R 2L 2R 2 2 3L 3R 4 Adhesive buffer Shaft seal ring Stop buffer Support for stop buffer Guide rail Carriage arm Variant B Reveal installation on the side Variant C At the bottom...

Страница 11: ...441 1 channel 6642 5 channel 6643 Nina io hand held transmitter bidi rectional touch display control 6220 Support for end piece of window shutter drive pair To be used with window shutter models with...

Страница 12: ...m or rub against its immediate sur roundings frame masonry etc The resistance of the folding shutter must not exceed a torque of 4 Nm during movement Remove any pre existing locking elements e g shutt...

Страница 13: ...he load capacity of the installation sub strates Notes The selection of the fastening method is de pendent on the substrate and is therefore exclusively your own responsibility Note that the lintel mu...

Страница 14: ...profile at at least four points Insert the electromechanical module into the frame on the side where the power supply enters Insert the drive modules into the installation profile move them as far as...

Страница 15: ...ing of the drive due to insufficient fastening Use security bore hole 2 3_B Security bore hole Insert the electromechanical module into the frame on the side where the power supply enters Insert the d...

Страница 16: ...e of installation profile min 5 mm Caution Property damage caused by sliding of the drive due to insufficient fastening Use security bore hole Security bore hole Insert the electromechanical module in...

Страница 17: ...arking Cable holder Wiring WARNING Electrical shock 230 V resulting from dam age to cable Protect mains cable against contact with the activated window shutter Caution Impairment of the antenna and th...

Страница 18: ...th guide rails on the drive Notes The swivel arms must be fitted in accord ance with one of these two recommenda tions a half open outside the end positions ob serving the sequence of the covered sash...

Страница 19: ...uding slats use the 6220 supports for end pieces of window shutter drive with the corresponding S4 screws When selecting screws for window shutters made of wood a decision that is the exclusive respon...

Страница 20: ...cation of proper function ing P 23 Activate radio wall transmitter Caution Do not press against the sensitive side of the wireless wall transmitter with the flat of the hand because otherwise unintend...

Страница 21: ...hes is correct If the sash with cover strip opens after or closes before the sash without cover strip the priority of the sashes is not correct and must be changed Self learning process Notes The teac...

Страница 22: ...exit the drive s self learning mode OFF beep ON The settings are not saved The self learning process must be repeated B Negative feedback from the drive The drive has detected an inappropriate settin...

Страница 23: ...e drive emits 2 signal tones and the folding shutter performs an open close movement beep beep The radio wall transmitter is now linked to the drive Verification of proper functioning Opening procedur...

Страница 24: ...us 3 35 52 Close the double shutter and mark the centre of rotation of guide lug B Afterwards open the double shutter and measure the distance from A to B A B Close the double shutter and divide the d...

Страница 25: ...Pivot bearing 3 locking set screw Crimped metal ribbon only when express hinges are used Notes The express hinges used must be secured against shifting in place as follows after the installation of th...

Страница 26: ...n called the prefer red position can be stored in the memory of the VOLETRONIC io shutter drive That position must not correspond to either the open or the closed position EHRET recommends selecting a...

Страница 27: ...obstacle recognition protects the VOLETRONIC io against damage and pre vents accidents If a sash encounters an obstacle when opening or closing the folding shutter is automatically stopped and moves...

Страница 28: ...arried out after the adjustment has been made Open the sashes halfway Press and hold the Open and Close buttons simultaneously for five seconds until the product performs an open close movement and em...

Страница 29: ...e sashes the closing force can be increased to a higher level as follows Activate the new setting mode see page 28 Open the sashes half way Press the buttons and of the wireless wall transmitter simul...

Страница 30: ...g to the pre configured mode deletes the changes to the leaf priority the direction of rotation the closing force setting all radio transmitters and sensors the favourite posi tion and deactivates the...

Страница 31: ...pre configured mode is active again Radio transmitter io Pure Option Notes As an option the VOLETRONIC io folding shutter drive can also be controlled by means of a io Pure wireless hand held transmi...

Страница 32: ...p tional 9 6 V 1600 mAh Notes The emergency battery must be recognised by the drive to be functional It can only be rec ognised when mains voltage is present If the battery is connected without mains...

Страница 33: ...Maintenance Insert the battery by placing it in the 5 fas tening hooks provided on the circuit board housing Make sure that the battery is firmly fitted in place Connect the battery to the circuit bo...

Страница 34: ...ig ured mode is active again Restore the initial configuration Notes Restoring the output configuration deletes all parameters of the drive These are the parameters mentioned in chapter List of settin...

Страница 35: ...s a selection aid see chapter List of setting parameters p 36 At any step you can cancel the current changes by pressing the key c In case of inactivity the display goes into sleep mode after a few se...

Страница 36: ...ng shutters with overlapping If these parameters have not been set at the factory they can only be changed after a reset of the drive to the pre configured mode Changing these parameters makes it nece...

Страница 37: ...t for drive operation Battery charge low Battery functional Battery fully charged Reserve ERROR code e 0 to J Product status error code If an error occurred during the last operation an error code app...

Страница 38: ...emergency battery must be recognised by the drive to be functional It can only be recognised when mains voltage is present If the battery is connected without mains voltage applied it will not functio...

Страница 39: ...o its normal state the power supply must be interrupted for 10 sec Then restore the power supply and start a self learning process Error 02 Motor e 2 Drive current of the multiphase motor Error motor...

Страница 40: ...eser Unterlage sowie technische nderungen behalten wir uns vor Diese Unterlage wurde mit beson derer Sorgfalt erstellt F r m glicherweise trotzdem vorhandene Fehler und deren Auswirkungen kann keine H...

Отзывы: