background image

7

Door frames

Remove this 
part

PVAC glue (D3)

 

ƒ

For wooden door frames, we recommend undercutting them – with the approval of the customer – according to the thickness of 
the flooring and the underlay.

 

ƒ

Install the flooring underneath the door frame – leave the necessary expansion gaps. In the event that your installation job will 
end underneath a door frame, we recommend that the locking part is removed from the protruding groove of the pre-installed 
panel with a chisel. The newly installed panel can then be pushed horizontally over the groove of the previously installed panel. 
This connection area has to be glued with a PVAC glue.

 

ƒ

If you have a door frame that cannot be shortened, e.g., one made of metal, we recommend that you close or cover the expansion 
gaps with sealant or suitable end profiles.

= +

 16 mm

a

b

c

Floor profiles

Install the required flooring profiles and the skirtings after the laminate flooring has been installed in the correct way as described 
above. Simple assembly instructions are enclosed with all the accessories.

Attention!

 With most types of profile, the base (sub-profile) taking the cover profile must be installed prior to installing the laminate 

floor.

Installation

Содержание JUSTclic!

Страница 1: ...Installation instructions Egger Laminate Flooring with JUSTclic installation system...

Страница 2: ...e of fast setting screed the measurements and limitis specified by the respective manufacturer shall apply The test material must be obtained from the lower one third of the screed During this process...

Страница 3: ...cting the function of the floor heating cooling system functional heating cooling Proof of the proper raising and lowering of the temperature of the heated screed structure in any season must be provi...

Страница 4: ...nate flooring with laminated Silenzio underlayer board on the reverse An additional insulation underlay is not permitted in this case 3 Before the installation Acclimatisation of the floor boards The...

Страница 5: ...observing the required gaps placing the spacers Figure 3 to 10 Start installing the 2nd row with the remaining panel of the 1st row if the latter is at least 200 mm long In the following rows the new...

Страница 6: ...to the top of the tongue on the short and long edge The glue should ooze out along the complete long and short edge after the panels have been connected together Excess sealing glue is easy to remove...

Страница 7: ...an then be pushed horizontally over the groove of the previously installed panel This connection area has to be glued with a PVAC glue If you have a door frame that cannot be shortened e g one made of...

Страница 8: ...exception of Aqua Laminate Flooring Only clean the laminate floor with a damp cloth Never use abrasives or scouring agents on the laminate floor Do not use cleaning products that may leave a residue...

Страница 9: ...41 301 20222 flooring egger com EGGER Drevprodukt Gagarin Ezhvinsky proezd 1 215010 Gagarin Oblast Smolensk Russia T 7 48135 79 300 F 7 48135 79 311 info ru egger com BR_flo_EGGER_installation_instruc...

Отзывы: