EFKA AB60D1472
63
Technician Level
Code no. 190 with control operation
Parameter
Designation
Unit
max
min
Preset
Ind.
146
0
=
Signal
high lift for walking foot
Off
3 0
0 A
1
=
Signal
h
i
gh lift for walking foot
at output M1
2
=
Signal
high lift for walking foot
at output M2
3
=
Signal
high lift for walking foot
at output M3,
if parameter 297 = 0
The connection of adapter cord and high lift walking
solenoid may have to be corrected according to the
setting of outputs M1...M3. See connection diagram and
adapter cable routing!
147
0
=
Signal
machine running
Off (exception M5)
3
0
0 *)
A
1
=
Signal
machine running
at output M1
2
=
Signal
machine running
at output M2
3
=
Signal
machine running
at output M3,
if parameter 297 = 0
The connection of adapter cord and solenoid valve
machine running
may have to be corrected according to
the setting of outputs M1...M3. See connection diagram
and adapter cable routing!
148
0
=
Signal
backtacking
Off
3 0
0
*) A
1
=
Signal
backtacking
at output M1
2
=
Signal
backtacking
at output M2
3
=
Signal
backtacking
at output M3,
if parameter 297 = 0
If parameter 290 = 7, the selected output takes the
function
chain suction
.
The connection of adapter cord and backtacking
solenoid may have to be corrected according to the
setting of outputs M1...M3. See connection diagram and
adapter cable routing!
152
thP Run-out time of the high lift walking speed
ms
500
80
150
A
153
Braking power at machine standstill
50
0
10 *)
A
155
Mode signal “run”
3
0
1
A
0 = Signal Off.
1 = Signal “run” On.
2 = Signal “run” switched on when the speed is
>3000
RPM.
3 = Signal with pedal <> 0.
156
t05 Switch-off delay for the signal “run”
ms
2550 **)
0
0
A
161
Direction of motor rotation
1
0
1 *)
A
0 = Clockwise rotation
1 = Counterclockwise rotation
172 POS
Display on the control:
Pos. 1 to 1A (LED 7 lights up)
Pos. 2 to 2A (LED 8 lights up)
173
Checking of the signal outputs and inputs using the
incorporated control panel
01 =
Free on socket ST2/34
02 =
Sewing foot lifting on socket ST2/35
03 =
Output M1 on socket ST2/37
04 =
Output M3 on socket ST2/27
05 =
Output M2 on socket ST2/28
06 =
Free
07 =
Output ML or M5 on socket ST2/32
OFF/ON = By actuating the switches connected to the
control, the function of these switches is
checked and displayed on the control.
OFF
is displayed with open switch and
ON
with closed switch.
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!
**) When programming the 3-digit or 4-digit control parameter values, the 2-digit or 3-digit value displayed must be
multiplied by 10.