5.2 Setting the reference position
(For detailed instructions refer to Chapter
6.9.1
Setting the Reference Position (Parameter 170)
Hold down the button and
switch on the controls
(Until Pos0 show for 1
second)
Press the E button
"P0" and a rotating
"u" are displayed
Turn the handwheel until
the rotating "u" disappears
Bring the handwheel to
the zero position (needle
up / OT)
Press the E button
Turn off
Note:
If the rotating "u" does not disappear after 10 rotations, change the direction of rotations.