Parameters Designation
Unit
Max
Min
Preset
Ind.
243
in4 Selection of input function on socket ST2/8 for input 4
0 = No function
All other functions of the keys as with parameter 240
145
0
0
244
in5 Selection of input function on socket ST2/5 for input 5
0 = No function
All other functions of the keys as with parameter 240
145
0
0
245
in6 Selection of input function on socket ST2/12 for input 6
0 = No function
All other functions of the keys as with parameter 240
145
0
0
246
in7 Selection of input function on socket ST2/9 for input 7
0 = No function
All other functions of the keys as with parameter 240
145
0
0
250
iFA Thread trimmer activation angle
Degrees 359
0
180
251
FSA Switch-off start backtack of thread tension release
ms
990
0
50
252
FSE Switch-on start backtack angle of thread tension release
Degrees 359
0
0
253
tFA Stopping time for thread trimming
ms
500
0
70
254
EF- Upper limit (Pa.204) clocking the sewing foot lifting switch
on period (ED) 1...100 %
%
100
1
100
255
Ev- Upper limit (Pa.213) clocking the sewing foot on period
(ED) 1...100 %1...100
%
100
1
100
259
FAE Activation start backtack angle of the thread trimmer
Degrees 359
0
0
263
ihP 0 =
Signal “high lift for walking foot”, when key is closed.
1 =
Signal “high lift for walking foot”, when key is open. (Function
only if parameter 137 = 1)
1
0
0
267
Abc Overlock mode: Interrupt the start count
And seam end initiation by light barrier uncovered
1
0
0
268
SEL Speed limitation via "select". (F290=55 & F290=74)
1
0
0
269
PSv Positioning shift
Incr.
100
0
10
270
PGm
Mode
for position sensor
6
0
0
0 = No external sensor. Positions are created via the sensor integrated in the motor.
5 = No position sensor available. The drive stops unpositioned. The thread trimmer function is
suppressed with this setting.
6 = With external sensor (e.g. IPG, HSM...).
272
trr Transmission ratio between motor shaft and machine shaft
(calculation formula see instruction manual!)
The transmission ratio should be determined and indicated as
precisely as possible!
40000
150
1000
280
kd1 Start backtack time output M1
ms
5000
0
0
281
kt1 ON period output M1
ms
5000
0
100
282
kd2 Start backtack time output M2
ms
5000
0
100
283
kt2 ON period output M2
ms
5000
0
100
284
kd3 Start backtack time output M3
ms
5000
0
200
285
kt3 ON period output M3
ms
5000
0
100
286
kd4 Start backtack time output M4
ms
5000
0
300
287
kt4 ON period output M4
ms
5000
0
100
288
kdF Start backtack time until sewing foot On
ms
5000
0
380
Содержание AB620A5035
Страница 98: ......
Страница 99: ...Instruction Manual with parameter List AB620A5035 Distribution For your notes ...
Страница 100: ... AB620A5035 Parameter List 94 For your notes ...
Страница 101: ... AB620A5035 Parameter List 95 For your notes ...
Страница 102: ... AB620A5035 Parameter List 96 For your notes ...
Страница 103: ... AB620A5035 Parameter List 97 For your notes ...