EFKA AB320A5200
67
Supplier Level
Code no. 311 with control operation
Code no. 3112 with control panel operation
Parameter
Designation
Unit
max
min
Preset
Ind.
240
in1
29 =
“Hemmer foot” signal Off (see parameter 296),
function effective only in the seam
30 =
High lift for walking foot, if sewing foot is On
31 =
Function “speed limitation bit0” (speed n11)
32 =
Function “speed limitation bit1” (speed n10)
(bit0 + bit1 = speed n9).
33 =
Speed n9 pedal controlled
34 =
Automatic speed n9 can be suspended by
pressing the pedal to pos. 0 (neutral)
35 =
Automatic speed n9 can be interrupted by
pressing the pedal to pos. -2
36 =
Automatic speed n9 without pedal
37 =
Speed n12 pedal controlled (break contact)
38 =
Automatic speed n12 without pedal
(break contact [N.C.])
39 =
Switch to the next pattern in TEACH IN
40 =
Switch back to the previous pattern in TEACH IN
41 =
Tape cutting only at machine standstill
42 =
Enable hot thread chain cutting or sewing foot
lifting. Function effective only in the chain stitch
mode.
43 =
No function
241
in2
Selection of input function on socket ST2/11
43
0
43
*)
A
for input 2
0 =
No function
All other functions of the keys as with parameter 240
242
in3
Selection of input function on socket ST2/6
43
0
43
*)
A
for input 3
0 =
No function
All other functions of the keys as with parameter 240
243
in4
Selection of input function on socket ST2/8
43
0
43
*)
A
for input 4
0 =
No function
All other functions of the keys as with parameter 240
244
in5
Selection of input function on socket ST2/5
43
0
43
*)
A
for input 5
0 =
No function
All other functions of the keys as with parameter 240
245
in6
Selection of input function on socket ST2/12
43
0
43
*)
A
for input 6
0 =
No function
All other functions of the keys as with parameter 240
246
in7
Selection of input function on socket ST2/9
43
0
43
*)
A
for input 7
0 =
No function
All other functions of the keys as with parameter 240
247
in8
Selection of input function on socket ST2/10
43
0
43
*)
A
for input 8
0 =
No function
All other functions of the keys as with parameter 240
248
in9
Selection of input function on socket ST2/13
43
0
43
*)
A
for input 9
0 =
No function
All other functions of the keys as with parameter 240
249
i10
Selection of input function on socket ST2/14
43
0
43
*)
A
for input 10
0 =
No function
All other functions of the keys as with parameter 240
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!