EFKA AB320A5200
63
Technician Level
Code no. 190 with control operation
Code no. 1907 with control panel operation
Parameter
Designation
Unit
max
min
Preset
Ind.
173
Sr4
Checking of the signal outputs and inputs using the
incorporated control panel or the V810/V820 control
panels
01 =
Backtacking on socket ST2/34
02 =
Sewing foot lift on socket ST2/35
03 =
Output M1 on socket ST2/37
04 =
Output M3 on socket ST2/27
05 =
Output M2 on socket ST2/28
06 =
Output M4 on socket ST2/36
07 =
Output M5 on socket ST2/32
08 =
Output M11 on socket ST2/31
09 =
Output M6 on socket ST2/30
10 =
Output M9 on socket ST2/25
11 =
Output M8 on socket ST2/24
12 =
Output M7 on socket ST2/23
13 =
Output M10 on socket ST2/29
OFF/ON = By actuating the switches connected to the
control, the function of these switches is
checked and displayed on the control.
OFF
is displayed with open switch and the
activated input
in1...i10
with closed switch.
179
Sr5
Control program number with index and identification
number. Upon pressing the appropriate key the data
will be displayed in succession.
V810
control panel display example:
Press the
E
key
!
Display e. g.
Sr
[°]
Press the
>>
key
!
Display e. g.
5200A
Press the
E
key
!
Display e. g.
981019
Press the
E
key
!
Display e. g.
15
Press the
P
key twice
!
Display
Ab320A
V820 control panel display example:
Press the
E
key
!
Display
F-179 Sr5
[°]
Press the
>>
key
!
Display e. g.
5200A
Press the
E
key
!
Display e. g.
98101915
Press the
P
key twice
!
Display
4000 Ab320A
See instruction manual for control display example.
180
rd
Number of reversing increments
degrees
359
0
175
*)
A
181
drd
Switch-on delay of reverse motor rotation
ms
990
0
10
*)
A
182
Frd
Reverse motor rotation On/Off
1
0
0
*)
A
183
FFm
Disabling of flip-flop functions at the seam end
3
0
0
A
0 = Flip-flop 1 (M6) and flip-flop 2 (M10) not disabled
at the seam end
1 = Flip-flop 1 (M6) disabled at the seam end
2 = Flip-flop 2 (M10) disabled at the seam end
3 = Flip-flop 1 (M6) and flip-flop 2 (M10) disabled
at the seam end
184
c6
Number of run-out stitches when unlocking the
stitches
254
0
20
*)
A
chain
185
chP
Stitch counting high lift for walking foot
stitches
254
0
0
A
186
FFi
Function “speed limitation n11”
1
0
0
*)
A
0 =
Speed limitation n11 On, when signal M10 is On.
Speed limitation n11 Off, when signal M10 is Off.
1 =
Speed limitation n11 Off, when signal M10 is On.
Speed limitation n11 On, when signal M10 is Off.
187
FFo
Function of signal M10 after “power On” (flip-flop 2)
1
0
0
*)
A
on socket ST2/29
0 =
Signal M10 Off / speed limitation n11
according to setting of parameter 186
1 =
Signal M10 On / speed limitation n11
according to setting of parameter 186
*)
Depending on the selected mode. See table at the beginning of the List of Parameters!