efacec EFAPOWER EV HC G3 Скачать руководство пользователя страница 9

E F A P O W E R   E V - H C   -   I N S T A L L A T I O N   A N D   U S E R   M A N U A L  

6 | 28                           

4

 

IMPORTANT SAFETY INSTRUCTIONS

 

SAVE THESE INSTRUCTIONS 

This manual contains important instructions that must be followed during installation of the EFAPOWER EV-HC 
Station. 
 

Grounding instructions 

The  EFAPOWER  EV-HC  Station  must  be  connected  to  a  grounded,  metal,  permanent  wiring  system;  or  an 
equipment-grounding conductor is to be run with circuit conductors and connected to the equipment grounding 
terminal or lead on the Electric Vehicle Supply Equipment (EVSE). Connections to the EVSE shall comply with all 
local codes and ordinances. 
 

Safety and compliance 

This document provides instructions to install the EFAPOWER EV-HC Station and should not be used for any other 
product.  Before installing the EFAPOWER EV-HC Station, you should review this manual  carefully  and consult 
with a licensed contractor, licensed electrician and trained installation expert to ensure compliance with local 
building practices, climate conditions, safety standards, and state and local codes. The EFAPOWER EV-HC Station 
should be installed only by a licensed contractor and a licensed electrician and in accordance with all local and 
national codes and standards. The EFAPOWER EV-HC Station should be inspected by a qualified installer prior to 
the initial use. Under no circumstances will compliance with the information in this manual relieve the user of 
his/her responsibility to comply with all applicable codes or safety standards. This document describes the most 
commonly-used installation and mounting scenarios. If situations arise in which it is not possible to perform an 
installation following the procedures provided in this document, contact EFACEC. EFACEC is not responsible for 
any damages that may occur resulting from custom installations that are not described in this document. 
 

No accuracy guarantee 

Reasonable effort was made to ensure that the specifications and other information in this manual are accurate 
and complete at the time of its publication. However, the specifications and other information in this manual are 
subject to change at any time without prior notice. 
 

Warranty information and disclaimer 

Your use of, or modification to, the EFAPOWER EV-HC Station in a manner in which the EFAPOWER EV-HC Station 
is not intended to be used or modified will void the limited warranty. Other than any such limited warranty, the 
EFACEC product

s are provided “AS IS,” and EFACEC and its distributors expressly disclaim all implied warranties, 

including any warranty of design, merchantability, fitness for a particular purposes and non-infringement, to the 
maximum extent permitted by law. 
 

Limitation of liability 

IN  NO  EVENT  SHALL  EFACEC  OR  ITS  AUTHORIZED  DISTRIBUTORS  BE  LIABLE  FOR  ANY  INDIRECT,  INCIDENTAL, 
SPECIAL,  PUNITIVE,  OR  CONSEQUENTIAL  DAMAGES,  INCLUDING  WITHOUT  LIMITATION,  LOST  PROFITS,  LOST 
DATA, LOSS OF USE, COST OF COVER, OR LOSS OR DAMAGE TO THE EFAPOWER EV-HC STATION, ARISING OUT 
OF  OR  RELATING  TO  THE  USE  OR  INABILITY  TO  USE  THIS  MANUAL,  EVEN  IF  EFACEC  OR  ITS  AUTHORIZED 
DISTRIBUTORS HAVE BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. 

 

Содержание EFAPOWER EV HC G3

Страница 1: ...EFAPOWER EV HC G3 HOME CHARGING STATION Installation and User Manual...

Страница 2: ...rademarks or registered service marks of their respective owners Symbols Index The following symbols are used in this manual to prevent accidents which may occur as a result of incorrect use of the ch...

Страница 3: ...9 5 2 2 Surface Preparation 10 5 2 3 Resources for Installation 10 5 2 4 Site Verification and Inspection 10 5 3 HANDLING AND PLACING 11 5 3 1 Packaging 11 5 3 2 Visual Inspection 11 5 3 3 Handling 11...

Страница 4: ...constitute a contractual obligation No part of this document may be photocopied reproduced or translated to other language without the written consent from EFACEC In case of any doubt regarding a sub...

Страница 5: ...7kVA 7 4kVA 11kVA and 22kVA EFAPOWER EV HC station is user friendly and safe Different models are available with power plug or socket When equipped with a socket the power cord plug is coupled into it...

Страница 6: ...ing with GB T20234 2 CE Units Type 2 according to EN 62196 2 GB Units Mode 3 according with GB T20234 2 EV Connection to EVSE CE units EN 61851 1 and IEC 61851 1 Case B and IEC 61851 1 Case C GB units...

Страница 7: ...61851 22 Electric vehicle conductive charging system Part 22 AC Electric Vehicle Charging Station 10 EN IEC 61000 6 1 Electromagnetic compatibility EMC Part 6 1 Generic standards Immunity for residen...

Страница 8: ...s Figure 3 EFAPOWEREV HC 3 7Parts RFID if applicable Output connection 3 7kVA 7 4kVA Output signaling Meter if applicable RCD and CB if applicable left side front side EV XX G3 YY 0F 00 G KK ZZP ZZ Me...

Страница 9: ...plicable codes or safety standards This document describes the most commonly used installation and mounting scenarios If situations arise in which it is not possible to perform an installation followi...

Страница 10: ...t ensure that the Unit can operate reliably while remaining within the range of its operating specifications 5 1 1 LOCAL CONDITIONS EFAPOWER EV HC Station has a protection degree of IP54 This Unit is...

Страница 11: ...r very low temperatures it s recommended to provide additional protection either inside a building or a shelter or providing a roof protection for the Unit See example in Figure 6 Figure 6 EFAPOWEREV...

Страница 12: ...suppressor please refer Figure 7 and Figure 8 Depending on the output of the Unit we can have several scenarios for the circuit breaker to be installed in the distribution board for each Unit The appr...

Страница 13: ...5mm2 4mm2 32 A 4mm2 4mm2 Tools Screwdriver for wall mount Crimping tool for power and earth cables Torque screwdriver with flat blade for input terminal blocks 5 2 4 SITE VERIFICATION AND INSPECTION C...

Страница 14: ...CKAGING EFAPOWER EV HC Station is shipped in a personalized package 493x400x187mm please refer to Figure 9 The Unit dimension is in Technical characteristics 2 1 5 3 2 VISUAL INSPECTION Check if the e...

Страница 15: ...t be hanging on the wires a Unplug the earth cable on it faston terminal b Unplug the flat cable on the board X14 c Unplug the card reader cable on the board X6 if applicable 3 Fix the Unit to the wal...

Страница 16: ...rs 5 3 4 2 and 5 3 4 3 EV HC11 EV HC22 Left grommet Charging Cable if applicable Middle grommet Input power cables refer chapters 5 3 4 2 and 5 3 4 3 Right grommet Communications refer chapter 5 3 4 4...

Страница 17: ...nected in accordance with the harmonized standards or local regulation The upstream protection is provided for the Unit To ensure protection to technicians during installation of the EFAPOWER EV HC pl...

Страница 18: ...Table 3 on page 9 5 3 4 4 COMMUNICATIONS IF APPLICABLE When applicable the communications on the EV HC shall be done through X2 double terminal marked with a red circle represented in both EV HC boxes...

Страница 19: ...e EV HC If it s not suitable the USB RS485 converter connected directly to the EV HC due to distance constraints alternative pre installation it s allowed Figure 15 A shielded communication cable of a...

Страница 20: ...n excel file ant therefore reports of charge associated to a specific RFID card can be generated ATTENTION There is a Maximum limit of the number of the chargers that can be connected this way 127 cha...

Страница 21: ...minal of the EV HC the respective RS 485 cables of the satellites network Is possible to have a network up to 25 satellite units In this solution the RFID card reader is only located on the Central Un...

Страница 22: ...ST NOT BE STARTED OR PUT INTO USE WITHOUT HAVING BEEN COMMISSIONED BY A FULLY TRAINED AND AUTHORIZED PERSON ALL SERVICING MUST BE PERFORMED ONLY BY QUALIFIED PERSONNEL DO NOT ATTEMPT TO SERVICE THE EF...

Страница 23: ...lever There is a test button for operation and differential protection test After connecting the charging station for the first time wait a few seconds and the EV HC Station should be ready to use AT...

Страница 24: ...pter 7 1 OUTPUT CONNECTOR EFAPOWER EV HC is prepared to charge electric vehicles according to the mentioned charging systems 7 1 1 TYPE 1 CONNECTOR Mode 3 7 1 2 TYPE 2 CONNECTOR Mode 3 7 1 3 TYPE GB C...

Страница 25: ...QUENCES FOR EV HC WITHOUT AUTHENTICATION The green light Ready indicates the EV HC is ready to be connected to a vehicle In the following figure is represented the operation sequence to start charging...

Страница 26: ...lowing figure is represented the stop charging sequence At this stage the station is ready to charge another vehicle NOTE If the user left the station charging and when returned light is blinking blue...

Страница 27: ...ith authentication or by disconnecting the cable from the car In the following figure are the sequences for each method NOTE If the user left the station charging and when returned light is blinking b...

Страница 28: ...damages caused after the warranty period but will gladly provide its customers with any technical consulting 8 1 PREVENTIVE MAINTENANCE This equipment must be kept in perfect condition to guarantee a...

Страница 29: ...D s EV HC without authentication The Homecharger is ready but the charging process didn t start The connector is not properly plugged into the vehicle Verify the correct connection to the vehicle The...

Страница 30: ...E F A P O W E R E V H C I N S T A L L A T I O N A N D U S E R M A N U A L 27 28 This Page Intentionally Left Blank...

Страница 31: ...E F A P O W E R E V H C I N S T A L L A T I O N A N D U S E R M A N U A L 28 28 This Page Intentionally Left Blank...

Страница 32: ...R EV HC G3 INSTALLATION AND USER MANUAL V 06 00 Rua Eng Frederico Ulrich Apartado 3078 4471 907 MOREIRA MAIA PORTUGAL Tel 351 229403241 Fax 351 229403209 serviceEEM efacec com www electricmobility efa...