lffiiI:
cc
-
-- ----
-- ----
lffiiI:
cc
-
-- ----
-- ----
STEP 3: Choosing per Axle High and Low Parameters
Using the plus or minus keys scroll to your "HIGH' pressure. When you reach your desired
pressure press and release the "SET' button again and 'LOW PRESSURE' will be displayed.
Use the plus or minus keys to set your low pressure. Press the set button again and the next
axle will flash "HIGH PRESSURE". Make your adjustments the same way as for the first axle.
Skip any axles that you are not using and just keep hitting the "SET" button until you get to the
axle that you want to set.
When you have finished setting your
parameters PRESS and HOLD the SET button
until the monitor beeps and you are back to
display mode. Keep in mind that the monitor
will
t
ime out in 40 seconds. So wright down
your settings before you start.
PROGRAMMING SENSORS TO THE MONITOR
METHOD 1 tabletop (this is the easiest way)
1.
Using the switch on the right side center of the monitor, push it up to turn on the monitor.
Place the monitor flat on the table in front of you. Then place your numbered sensors on the
table about a foot away from the monitor.
2.
Press and hold the CODE button on the monitor left side middle button until
you hear the
beep. At this time, you will see all 26 tires on the monitor screen, and the right
front tire should
be flashing.That is
t
ire number 1. Following your diagram on the back of your manual, place
the first sensor on the table
touching the base of the
next to the
SET
b
utton
. You will see "FFF
FFF" on the
screen . All F's means that
a
sensor is not programmed yet
to that location
. Then
press and release the
code button
very quickly
one time. The monitor will beep, and
the
sensor's
code
will be displayed. Press the
plus button to go to the next tire and do the same
and so on
until all sensors are programmed
.
3.
When you have programmed the last sensor, press the "CODE" button down until the
monitor sets off the alarm
or just turn the monitor off
. Then turn the monitor on again to make
sure the tires
are programmed in the
w
right position.
4.
Install your sensors to the valve stems in the order that you programmed them. Give the
monitor 5 to 1 O minutes to register all the sensors. Once the sensors are synced you will not
have to re-sync unless you turn off the monitor. You can leave the monitor turned on by the
monitor's battery power. The monitors internal battery will run for 60 hours
or 30 days
between
charges.
NOTE:
If you get an ID LF (low frequency), error code, hit the sensor hard on the table
to wake it up and repeat. If you still get the Id LF repeat, press the CODE button
and release, pause and then press the CODE button and release again. If it still
gives ID LF then check the battery voltage with a volt meter. The voltage on a
fresh battery should be 3.3v. If it is below 2.9v replace the battery with a fresh
one.
10 - - - - - - - - - - - - - - -