© Edwards Limited 2018. All rights reserved.
Page 7
Edwards and the Edwards logo are trademarks of Edwards Limited.
Technical data
B722-40-880 Issue H
2
Technical data
2.1
General
2.2
Pumping media
Table 2 - General data
General items
Reference data
Performance
Refer to
Dimensions
Refer to
Maximum inlet flange temperature
ISO63 / ISO100 / NW40
70 °C with cooling water
DN63CF (EXT75DX)
100 °C bakeout, with cooling water
Maximum permitted external magnetic field
EXT75DX
5 mT
Pollution degree
EN61010, Pollution Degree 2
Equipment type
Fixed equipment, for indoor use only
Enclosure protection (installed)
EXT75DX and 75DXi/NW25
IP50
EXT75DXi/NW16
IP50
EXT75iiDX
Contact Edwards for details
WARNING
Vent dangerous gases and gas mixtures safely. Do not expose people to these gases. If pumping
hazardous gases or vapours, observe the safety recommendations of the supplier of the gas/
vapour.
WARNING
Do not use the DX pump to pump pyrophoric or explosive gas mixtures, as it is not suitable for this
purpose. The pump and its connections are not designed to contain an explosion.
WARNING
In the interstage versions of the DX pumps, gas pumped through the interstage port will mix with
gas pumped through the pump inlet. Ensure that the gases will not react or combine to form
dangerous gases and substances.
WARNING
Do not expose any part of the human body to vacuum.