3.

 

Wrap the respiration belt tightly, without causing 
discomfort,  around  the  user’s  lower  ribs  and 
diaphragm area. 

4.

 

Ensure  that  the  rubber  tubing  connected  directly 
to the respiration belt is situated above the user’s 
naval facing downwards. 

5.

 

Close  the  air  pressure  release  valve  by  twisting 
the metallic knob until it tightens. 

6.

 

Using  the  hand-pump  fill  the  respiration  belt’s 
bladder  until  it  forms  a  snug  but  not 
uncomfortable fit. 

7.

 

Run  an  experiment  following  one  of  the 
following guides. 

 

Quick start procedure: 

 

PC or Mac Computer 

 

Materials needed: 
 

 

900-255 Respiration Sensor 

 

900-213 USB Module 

 

USB  to  mini  USB  cable  (included  with  the  900-
213 module) 

 
Your  respiration  sensor  needs  to  be  connected  to  a 
900-213 module.  The 900-213 module then connects 
to  a  computer  via  a  USB  to  mini-USB  cable.    Please 
note  that  you  cannot  plug  the  respiration  sensor 
directly into the computer. 
 
Resident  PC  software  and  browser  based  application 
can be downloaded for free at 

www.edulab

 as well as 

a full software user guide.

  

Note:

  Make  sure  not  to  download  and  install  both 

types of software they will conflict on the computer. 

 
 

 

Содержание 900-255

Страница 1: ...Edu Logger Respiration Monitor Belt Logger Sensor Guide 900 255...

Страница 2: ...5 sensors are exercise studies human health studies athlete comparisons respiration abnormalities and many more The respiration sensor uses the following units of measure Arbitrary analog units Arb An...

Страница 3: ...following one of the following guides Quick start procedure PC or Mac Computer Materials needed 900 255 Respiration Sensor 900 213 USB Module USB to mini USB cable included with the 900 213 module Yo...

Страница 4: ...t button this will open a graph below 8 Click on the Module setup button located on the respiration sensor icon in the module window to change the sensor settings if need be 9 Click on the experiment...

Страница 5: ...ni to USB cord and plugging it into your computer or a wall charger Please note this function is only available on 900 268 units with the USB icon on the cover 5 For further 900 268 instructions or th...

Страница 6: ...experiment set up button to change the experiment settings if need be Experiment duration for example 16 To run an experiment and collect data select On Line experiment then select Run 17 If you have...

Страница 7: ...ials needed to configure your offline experiment 900 213 Module or 900 268 module or 900 272 Module USB to mini USB cable included with the 900 213 module Procedure 1 Connect the respiration sensor di...

Страница 8: ...can be stored at one time on the 900 255 respiration sensor Restoring sensor s factory default settings Procedure 1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the respiration sen...

Страница 9: ...t Resolution 1 Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Respiration monitor belt attached to the sensor body by a flexible rubber hose Hand pump with...

Страница 10: ...Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The pressure sensor uses the piezoresistive effect The tr...

Страница 11: ...plastic body in any liquid Do not allow liquid into the respiration sensor s body After use gently wipe away any foreign material from the respiration sensor Store in a box at room temperature out of...

Страница 12: ...12 Thank you for using Edu Logger W www edulab com E info edulab com V10012013...

Отзывы: