Procedure: 

1.

 

Install the Edu-Logger software 

2.

 

Connect the 900-213 module to the PC or Mac 

3.

 

Connect  the  respiration  sensor  to  the  900-213 
module (they directly plug together).  Please note 
there is no calibration required for this sensor. 

4.

 

Open the Edu-Logger software. 

5.

 

Once a respiration sensor logo appears on the left 
side  of  the  screen  the  probe  has  been 
automatically  identified  and  you  can  begin 
experimentation. 

6.

 

If  the  respiration  sensor  is  not  automatically 
identified then click the “Search for sensors” icon 
to find the sensor. 

7.

 

Select the  “On-line experiment” button; this  will 
open a graph below. 

8.

 

Click  on  the  “Module  setup”  button  located  on 
the respiration sensor icon in the module window 
to change the sensor settings if need be. 

9.

 

Click on the "experiment set up" button to change 
the  experiment  settings  if  need  be  (experiment 
duration for example). 

10.

 

The respiration sensor will give a live reading in 
the box to the left of the screen while plugged in. 

11.

 

To run an experiment and collect data click “Run 
experiment”. 

12.

 

To  end  data  collection  early,  click  “Stop 
experiment”. 

 

Tablet, smart phone device 

 

Materials needed: 

 

900-255 Respiration Sensor 

 

900-268 WiFi module 

 

900-215 Battery 

 
Your  respiration  sensor  needs  to  be  connected  to  a 
900-268  module.  The  900-268  module  will  create  a 
closed  Edu-Logger  WiFi  network  which  will  stream 

Содержание 900-255

Страница 1: ...Edu Logger Respiration Monitor Belt Logger Sensor Guide 900 255...

Страница 2: ...5 sensors are exercise studies human health studies athlete comparisons respiration abnormalities and many more The respiration sensor uses the following units of measure Arbitrary analog units Arb An...

Страница 3: ...following one of the following guides Quick start procedure PC or Mac Computer Materials needed 900 255 Respiration Sensor 900 213 USB Module USB to mini USB cable included with the 900 213 module Yo...

Страница 4: ...t button this will open a graph below 8 Click on the Module setup button located on the respiration sensor icon in the module window to change the sensor settings if need be 9 Click on the experiment...

Страница 5: ...ni to USB cord and plugging it into your computer or a wall charger Please note this function is only available on 900 268 units with the USB icon on the cover 5 For further 900 268 instructions or th...

Страница 6: ...experiment set up button to change the experiment settings if need be Experiment duration for example 16 To run an experiment and collect data select On Line experiment then select Run 17 If you have...

Страница 7: ...ials needed to configure your offline experiment 900 213 Module or 900 268 module or 900 272 Module USB to mini USB cable included with the 900 213 module Procedure 1 Connect the respiration sensor di...

Страница 8: ...can be stored at one time on the 900 255 respiration sensor Restoring sensor s factory default settings Procedure 1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the respiration sen...

Страница 9: ...t Resolution 1 Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Respiration monitor belt attached to the sensor body by a flexible rubber hose Hand pump with...

Страница 10: ...Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The pressure sensor uses the piezoresistive effect The tr...

Страница 11: ...plastic body in any liquid Do not allow liquid into the respiration sensor s body After use gently wipe away any foreign material from the respiration sensor Store in a box at room temperature out of...

Страница 12: ...12 Thank you for using Edu Logger W www edulab com E info edulab com V10012013...

Отзывы: