After  the  experiment  has  concluded  (when  the 
“Start/Stop”  button  is  pressed  again  or  the  data 
collection period ends) connect the sensor to your 
chosen device. (full instructions in each device’s 
quick start procedure section) 

5.

 

Open Edu-Logger software. 

6.

 

Click the “Off-line experiment” button. 

7.

 

Click the “Load data from sensors” button.  

8.

 

Select  which  experimental  data  to  upload.  (5 
experimental  runs  can  be  stored  at  one  time  on 
the 900-255 respiration sensor) 

 
 
 
 

Restoring sensor’s factory default settings: 

 

Procedure: 

 
1.

 

Connect  the  900-213  to  a  PC,  Mac,  tablet,  or 
smart device. 

2.

 

Connect  the  respiration  sensor  to  a  900-213 
module (they directly plug together).  Please note 
there is no calibration required for this sensor. 

3.

 

Open the Edu-Logger software. 

4.

 

Click the “Tools” icon. 

5.

 

Click  the  “Restore  sensor’s  factory  defaults”  on 
the menu. 

6.

 

If  prompted  to  clear  the  graph,  click  either  the 
“Off-line  experiment”  or  “On-line  experiment” 
(whichever you are using). 

7.

 

Click “Clear experiment results”. 

8.

 

Resume from step 4. 

 
 
 
 
 

Содержание 900-255

Страница 1: ...Edu Logger Respiration Monitor Belt Logger Sensor Guide 900 255...

Страница 2: ...5 sensors are exercise studies human health studies athlete comparisons respiration abnormalities and many more The respiration sensor uses the following units of measure Arbitrary analog units Arb An...

Страница 3: ...following one of the following guides Quick start procedure PC or Mac Computer Materials needed 900 255 Respiration Sensor 900 213 USB Module USB to mini USB cable included with the 900 213 module Yo...

Страница 4: ...t button this will open a graph below 8 Click on the Module setup button located on the respiration sensor icon in the module window to change the sensor settings if need be 9 Click on the experiment...

Страница 5: ...ni to USB cord and plugging it into your computer or a wall charger Please note this function is only available on 900 268 units with the USB icon on the cover 5 For further 900 268 instructions or th...

Страница 6: ...experiment set up button to change the experiment settings if need be Experiment duration for example 16 To run an experiment and collect data select On Line experiment then select Run 17 If you have...

Страница 7: ...ials needed to configure your offline experiment 900 213 Module or 900 268 module or 900 272 Module USB to mini USB cable included with the 900 213 module Procedure 1 Connect the respiration sensor di...

Страница 8: ...can be stored at one time on the 900 255 respiration sensor Restoring sensor s factory default settings Procedure 1 Connect the 900 213 to a PC Mac tablet or smart device 2 Connect the respiration sen...

Страница 9: ...t Resolution 1 Max sample rate S sec 100 Sensor features Fully digital data Rugged plastic ergonomic case Respiration monitor belt attached to the sensor body by a flexible rubber hose Hand pump with...

Страница 10: ...Lux ppm for example The sensor is pre calibrated at the factory The built in software in the logger can be upgraded at any time using software The pressure sensor uses the piezoresistive effect The tr...

Страница 11: ...plastic body in any liquid Do not allow liquid into the respiration sensor s body After use gently wipe away any foreign material from the respiration sensor Store in a box at room temperature out of...

Страница 12: ...12 Thank you for using Edu Logger W www edulab com E info edulab com V10012013...

Отзывы: