3
Introduction
NOTE. TB SMEANS TERMINAL CONNECTOR
EDP-C2
consists in a complete electronic concept which allows a greater control of the
working parameters resulting in an increase lifespan of the generator and the
electromagnet.
The controller is easy to install. It only needs a few connections.
The controller adapts to most generators with a range of (180 to 300 volts DC with a
maximum of 5 amps on the field).
The current of electromagnet does not affect the controller.
The system tolerates ± 14% of the generator RPM variation without affecting the
efficiency or broke the controller, which is very useful for the system that use hydraulic
driven generators.
The controller’s display shows the voltage and the amperage applied to the electromagnet.
The controller also shows the modulation and voltage applied to the generator’s field .
The information displayed by the controller will allow us to guide you, even at distance,
for the adjustments, how to increase the efficiency and how to fix your lifting equipment.