8
Programming of the parameters
Press the right arrow during 2 second. With the help of the two others arrows, select code ‘42’ for
the main parameters or the code ‘72’ for the auxiliaries input and output.
Press on the right arrow
Use upward or downward arrows to scroll through the parameters.
When you see the parameter that you would like to adjust press right arrow.
Use the upward or downward arrows to change the value settings.
Then, press on the right arrow; this will confirm the changes.
To exit the programming mode, press on the downward arrows as many time as it takes
to come back to the main menu.
Parameters description and original settings in
parenthesis
If you come across this drawing
, it means that you can try
some settings for the dropping before accepting them with the
right arrow.
ACCES CODE 42
LANGUAGE
Language used on the screen
(English)
MAGNET VOLTAGE
Voltage to the electromagnet when lifting material
From 200 to 260 volts DC
(230 volts)
GENERATOR AMP.
Alarm amperage from 15 to 200 amps max .
(200)
AUTO PARAMETERS FOR DROPPING
The controller will apply, by itself, the best dropping parameters he can to
accomplish the work efficiently.