![EDN RADIASOL T120 Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/edn/radiasol-t120/radiasol-t120_technical-manual_2362477030.webp)
ENERGY BY NATURE
30
CAUTION. Never leave RADIASOL
exposed to the sun without water. If the
exchanger needs to be left empty, make
sure it is protected by a fire-resistant and
non-transparent cover.
CAUTION. It is compulsory to install a
thermostatic mixer valve downstream of
the connector (hot water outlet) to avoid
users to get burned and to optimise the
exchanger’s performance.
CAUTION. EDN recommends installing
RADIASOL in limited access areas. The
surfaces’ high temperatures and the
safety valve’s sudden opening may cause
serious injuries. Please keep in mind that,
in case of ground installation, the area
should fenced off.
RADIASOL must be installed on suitable
bolsters designed by a structural engineer,
and equipped to support the exchanger’s
gross weight (see Technical Information).
Snow, wind and seismic action must be
calculated according to the place chosen
for the installation and in compliance with
the national laws.
The frame anchoring inserts (not
included) must be suitable for the surface
type and the bolsters’ material.
CAUTION. Central heating installation
and operation must comply with appli-
cable local laws and regulations.
CAUTION: Before installation, please
store the packaged equipment in a
dry place, and on a steady ground or
shelving.
PPE
Accessories
Features – use
Normative
reference
Light protective
gloves
For mechanical operations: resistant to
abrasion, cuts, tearing and puncture
EN 388
Lace-up safety
footwear
With anti-slip sole, anti-static, anti-puncture
EN 345
Industrial
safety helmet
Insulating, chin-strap harness structure (when
working near overhangs at a height of 1100 mm
- 2300 mm)
EN 397
Protective
clothing
Made with anti-static fabrics
EN 1149
EN 430
“Linee Vita®“
equipment
Stainless steel protective panels against falls
- especially during the first installation and/
or for maintenance operations.
UNI EN 795
Lightning protection
EN 62305
Roof works dangers:
• Make sure that all necessary safety precautions are taken
during roof works, especially to reduce the risk of falls.
• Protective safety clothing should be worn at all times.
• Once works are completed, the assembly kit fixing,
the framework and the exchanger should be carefully
checked.
The table data can be modified, updated and/ or
superseded by applicable laws which must be strictly
complied with: ANY OTHER AND/OR NEW LAWS
APPLICABLE AT THE TIME OF OPERATION SHALL
PREVAIL OVER THIS MANUAL.
3.2 Delivery and handling
RADIASOL
is delivered in a cardboard box containing
the follow equipment:
- installation, use and maintenance manual
- safety valve
- non-return valve
- 3/4 brass fittings kit
- air outlet valve (only for horizontal installation)
Ground and roof frames (optional) are delivered in a
separated package, together with assembly screws.
Exposure time to receive partial thickness burns
Temperature
70°C
60°C
50°C
Adults
1 sec
5 sec
5 min
Children 0-5 years
---
1 sec
2,5 mins
EDN recommends that the professionals dealing with
the exchanger’s installation and routine and emergency
maintenance should use the following Personal
Protective Equipment (PPE) and related accessories.