EDN RADIASOL T120 Скачать руководство пользователя страница 16

ENERGY BY NATURE

16

Where: Istanbul - TURKEY 

Type of installation: Sports centre

Where: Misano Adriatico (Emilia-Romagna) - ITALY 

Type of installation: Accommodation facility

Содержание RADIASOL T120

Страница 1: ...ENERGY BY NATURE TECHNICAL MANUAL RADIASOL the solar thermal system that warms even in winter without boiler and antifreeze devices THE ORIGINAL...

Страница 2: ...2 ENERGY BY NATURE...

Страница 3: ...necessity According to this medieval saying by William of Ockham we should only use the elements we really need by shaving off hence the expression Ockham s Razor that which is superfluous Following...

Страница 4: ...ctual need pag 05 How it Works pag 06 09 Building quality Water analysis pag 10 Investing in RADIASOL pag 11 Models and climate types pag 12 Sizing criteria pag 13 Examples of installed systems pag 14...

Страница 5: ...nt need for maintenance due to the presence of forced circulation pumps electrical switchboards antifreeze devices additional expansion vessels bulky storage tanks with double coils and so on 3 Critic...

Страница 6: ...or with cylindrical tubes interconnecting containing water that absorbs solar radiation directly through the gasified double glazing It uses the best available solar radiation thanks to its particular...

Страница 7: ...em aesthetics and simplicity No maintenance needed TRADITIONAL SYSTEMS In conventional systems forced circulation natural circulation or vacuum the heat exchange between solar energy and water takes p...

Страница 8: ...red radiation as independent from the product s manufacturing quality and if we consider radiation and conduction losses as negligible the latter may be effectively curtailed via an excellent insulati...

Страница 9: ...vertical position has a diameter height ratio well above the generally required standards 2 5 1 The picture shows RADIASOL in vertical position Figure 1 with an inlet water temperature of 15 C In thi...

Страница 10: ...rs and various applications in hot water it should not be used by directions of European steel centres with water containing more than 80 ppm of chloride and sulphates see warranty RADIASOL can be bui...

Страница 11: ...early production per annum for RADIASOL T200D model facing South North if below the equator line in climate zone E with a 35 40 inclination Daily average production per annum with a traditional system...

Страница 12: ...with RADIASOL systems installed through which EDN executes performance tests throughout the year AVERAGE ANNUAL INSOLATION VALUES kwh m2 Temperature controlled air volume Double glazed unit Resistor D...

Страница 13: ...industrial Benefits RADIASOL s thermal performance allows a drastic reduction of depreciation times for this type of installations Production of electricity in combination with low temperature heat pu...

Страница 14: ...ENERGY BY NATURE 14 Where Cecina Tuscany ITALY Type of installation Terraced houses EXAMPLES OF INSTALLED SYSTEMS 14 Where Sondrio Lombardy ITALY Type of installation Independent house...

Страница 15: ...ENERGY BY NATURE 15 Where Drome French Alps FRANCE Type of installation Independent houses Where Southampton UNITED KINGDOM Type of installation Independent house...

Страница 16: ...ENERGY BY NATURE 16 Where Istanbul TURKEY Type of installation Sports centre Where Misano Adriatico Emilia Romagna ITALY Type of installation Accommodation facility...

Страница 17: ...ENERGY BY NATURE 17 Where Mexico City MEXICO Type of installation Independent House Where Essen GERMANY Installation Type of installation Independent house...

Страница 18: ...ENERGY BY NATURE 18 Where Gabicce mare Emilia Romagna ITALY Type of installation Seaside resort Where Athens GREECE Type of installation University facility...

Страница 19: ...ENERGY BY NATURE 19 Where San Jose COSTA RICA Type of installation Independent House Where Fiumicino Rome ITALY Type of installation Residential complex...

Страница 20: ...ENERGY BY NATURE 20 Where Todi Umbria ITALY Type of installation Farmhouse Where Cairo Egypt Type of installation Commercial offices...

Страница 21: ...ENERGY BY NATURE 21 TECHNICAL DATA MODELS T250D T250S T200D T200S T150D T150S T120D T120S...

Страница 22: ...g varnish 0 5 gloss with maximum resistance 300 C Aluminum casing 5000 series with excellent resistance even in seaside places Polyurethane thermal insulation 0 028 W mK Predisposition for thermo regu...

Страница 23: ...g varnish 0 5 gloss with maximum resistance 300 C Aluminum casing 5000 series with excellent resistance even in seaside places Polyurethane thermal insulation 0 028 W mK Predisposition for thermo regu...

Страница 24: ...stance 300 C Aluminum casing 5000 series with excellent resistance even in seaside places Polyurethane thermal insulation 0 028 W mK Predisposition for thermo regulated resistance 1 63 m2 Technical Da...

Страница 25: ...tance 300 C Aluminum casing 5000 series with excellent resistance even in seaside places Polyurethane thermal insulation 0 028 W mK Predisposition for thermo regulated resistance 1 94 m2 Technical Dat...

Страница 26: ...General information before installation 2 1 Usage requirements 2 2 Marking data 2 3 Recycling and disposal 3 Installation instruction Technical Data 3 1 Safety rules 3 2 Delivery and Handling 4 Hydra...

Страница 27: ...ontained in this Manual may cause serious damages to people animals and objects The manufacturer reserves the right to modify the product and its technical documentation in order to improve its featur...

Страница 28: ...tures below 10 C Always insulate adequately external piping to prevent freezing winter CAUTION EDN shall not be liable in any way for any damages and injuries occurringtousers operators thirdparties a...

Страница 29: ...m Exposure of the exchanger and assembly materials to solar radiations may cause serious burns during handling operations Please read carefully this section before installing the exchanger Follow the...

Страница 30: ...twear With anti slip sole anti static anti puncture EN 345 Industrial safety helmet Insulating chin strap harness structure when working near overhangs at a height of 1100 mm 2300 mm EN 397 Protective...

Страница 31: ...allation For the hydraulic connection use pipes suitable for continuing operating temperatures higher than 100 C EDN recommends using properly insula ted tubes and external fittings low and return to...

Страница 32: ...orking CAUTION the resistance has to be inserted inside the exchanger in the right slot through the lower cable gland Do not forget to check the close fitting of the top cable gland to avoid water see...

Страница 33: ...HOT WATER COLD WATER HYDRAULIC KIT EXPANSION VESSEL NON RETURN VALVE BOILER ELETTRICO HEAT PUMP Indicative schemes 6 INSTALLATION SCHEMES The absence or the inefficiency ofnon returnvalve compulsory...

Страница 34: ...VESSEL BOILER NUN RETURN VALVE Connection with fireplace or stove pellet Parallel connection SAFETY VALVE AUXILIARY BOILER Indicative schemes The absence or the inefficiency ofnon returnvalve compulso...

Страница 35: ...or grounding system 4 legs Distance of the frames 7 FRAMES INSTALLATION RADIASOL must be built on suitable bolsters calculated by a structural engineer equipped to support the gross weight see Technic...

Страница 36: ...not provided suitable for the bolster material It always needs to protect the installation from the possible tipping using right systems Kit contents All models 2 tubes 25x25x2040mm 2 tubes 25x25x1095...

Страница 37: ...contents 4 screws M8x20 4 crew plate 1 screw for grounding system 4 brackets A T150d T150s 516 mm T200d T200s 729 mm A T250d T250s 910 mm A All models 1905 mm B Distances of the frame Subtile kit is n...

Страница 38: ...tubes 25x25x798mm T250d T250s 2 tubes 25x25x1220mm T200d T200s 2 tubes 25x25x1010mm The frames can withstand a maximum wind speed of 108 km h see Eurocode standards EDN does not guarantee the frame fo...

Страница 39: ...fit from the free warranty it is required to install all components see paragraph 5 and to respect water parameters see the table below Do not use RADIASOL with different values PARAMETERS ACCEPTABLE...

Страница 40: ...ERGY BY NATURE 40 EDN s r l Zona Ind Via dei Facocchi 6 Ph 39 075 8044354 Fax 39 075 8042916 06081 S Maria degli Angeli Assisi PG www ednenergia it info ednenergia it P Iva 02889760548 ENERGY BY NATUR...