68
REMOTE Command Reference
VER
Version Information Request
stxVER;
Transmit this when you want to check the V-440HD’s version. The
version information is returned.
*
For more details on version information, refer to “VER Version
Information” on this page.
ACS
Active Sensing Request
stxACS;
Transmit this when you want to check the V-440HD’s status.
ACK is returned when no operation is being performed by the V-
440HD.
DAT
Data Transmission
stxDAT:aaaa,bbbb;
aaaa: Address (aaaa, bbbb are in hexadecimal)
bbbb: Data
This overwrites the data at the specified address.
After the required data is transmitted, FFFF,xxxx; is transmitted as
the final string of the command, and the data is written (xxxx
represents the data version).
ACK is returned by the V-440HD upon proper reception of the
command.
❍
“Serial Data Tool,” software which can be used for backing up
the V-440HD’s settings (for Windows XP only), is available on
the Roland Systems Group website. Download the software
from the URL shown below.
Note that Roland provides no user support whatsoever for
“Serial Data Tool.”
❍
A “SERIAL REMOTE/MIDI Address Map” providing a list of
addresses has been prepared separately from the Owner’s
Manual. Download the PDF file from the URL shown below
(free of charge).
[Roland Systems Group Website]
http://rolandsystemsgroup.net
XON Flow Control
XON
XOFF Flow Control
XOFF
In the following, stx(02H), ACK(06H), and Xon(11H)/Xoff(13H) are
control codes.
ACK
Acknowledgment of Proper Reception
ACK
This is transmitted when a command is received properly.
ERR
Error Information
stxERR:a;
a: 0 (syntax error)
Error in the syntax of the received command.
2 (busy error)
V-440HD busy, command cannot be
processed.
5 (out of range error) Number in received command is out of range.
20 (something error) Other error. Transmitted when the V-440HD
is unable to process the command properly.
VER
Version Information
stxVER:”a”,”b”,”c”;
a: Model Name
b: Version
c: Reserved
This is transmitted when the V-440HD receives a VR command
version. The version information is transmitted as an ASCII
character string.
DAT
Data Transmission
stxDAT:aaaa,bbbb;
aaaa: Address
(aaaa, bbbb are in hexadecimal)
bbbb: Data
The data is transmitted to the specified address.
After the required data is transmitted, FFFF,xxxx; is transmitted as
the final string of the command, and the data is written (xxxx
represents the data version).
❍
“Serial Data Tool,” software which can be used for backing up
the V-440HD’s settings (for Windows XP only), is available on
the Roland Systems Group website. Download the software
from the URL shown below.
Note that Roland provides no user support whatsoever for
“Serial Data Tool.”
❍
A “SERIAL REMOTE/MIDI Address Map” providing a list of
addresses has been prepared separately from the Owner’s
Manual. Download the PDF file from the URL shown below
(free of charge).
[Roland Systems Group Website]
http://rolandsystemsgroup.net
XON Flow Control
XON
XOFF Flow Control
XOFF
Commands Transmitted from the
V-440HD to External Devices
Содержание V-440HD
Страница 92: ...04349834 06 09 1N 0 4 3 4 9 8 3 4 0 1 ...