MIDI implementation
■
System common message
On the UR-80 you can assign the following system common messages to LED mode
and receive them.
●
MTC quarter frame
Status
2nd byte
F1H
mmH
mm = Message type/value
●
Song position pointer
Status
2nd byte
3rd byte
F2H
mmH
llH
mm, ll = Song position:
00 00H - 7F 7FH (0-16383)
●
Song select
Status
2nd byte
F3H
mmH
mm = Song number:
00 00H - 7F 7FH (0-16383)
●
Tune request
Status
F6H
■
System realtime message
*
In addition to Active Sensing messages (which are always received), the UR-80
can receive the following System Realtime messages that you assign in LED
mode.
●
Timing clock
Status
F8H
●
Start
Status
FAH
●
Continue
Status
FBH
●
Stop
Status
FCH
●
Active sensing
Status
FEH
*
When Active Sensing is received, the UR-80 will begin monitoring the interval
between all subsequent messages. If a gap of greater than 420 ms between
messages occurs while monitoring is being performed, the UR-80 will transmit
All Sound Off and Reset All Controller messages to all ports.
●
System reset
Status
FFH
■
System exclusive messages
●
Universal non-realtime system exclusive message
❍
Identity request message
Status
Data byte
Status
F0H
7EH, dev, 06H, 01H
F7H
Byte
Explanation
F0H
Exclusive status
7EH
ID number (Universal non-realtime system exclusive message)
dev
Device ID (10 or 7FH (Broadcast))
06H
Sub ID #1 (General Information)
01H
Sub ID #2 (Identity Request)
F7H
EOX (End of Exclusive)
●
Data transmission
The UR-80 can use Bulk Dump (p. 383) to transmit the data of its internal memory
sets (p. 349).
❍
Data Set 1DT1 (12H)
This message transmits the actual data, and is used to load the data into the device.
Status
Data byte
Status
F0H
41H, 10H, 00H, 68H, 12H,
aaH, ddH, ...eeH, sum
F7H
Byte
Explanation
F0H
Exclusive status
41H
ID number (Roland)
10H
Device ID (For the UR-80, fixed at 10H)
00H
Model ID #1 (UR-80)
68H
Model ID #2 (UR-80)
12H
Command ID (RQ1)
aaH
Address
ddH
Data
:
:
:
eeH
Data
sum
Checksum
F7H
EOX (End of Exclusive)
*
The amount of data that can be transmitted at once is fixed for each type of data.
Data that does not have the specified starting address and data size will not be
received. Refer to the explanation in 3. Bulk Dump (p. 383).
*
There must be an interval of at least 40 ms between each exclusive message that
is sent.
Содержание UR-80
Страница 27: ...27 Espa ol Italiano Fran ais Deutsch English Basic operation...
Страница 66: ...MEMO...
Страница 67: ...Espa ol Italiano Fran ais Deutsch English 67 Advanced operation...
Страница 93: ...93 Espa ol Italiano Fran ais Deutsch English Grundlegende Bedienung...
Страница 132: ...MEMO...
Страница 133: ...Espa ol Italiano Fran ais Deutsch English 133 Erweiterte Bedienung...
Страница 159: ...Espa ol Italiano Fran ais Deutsch English 159 Fonctionnement de base...
Страница 198: ...MEMO...
Страница 199: ...Espa ol Italiano Fran ais Deutsch English 199 Fonctionnement avanc...
Страница 225: ...Espa ol Italiano Fran ais Deutsch English 225 Nozioni di base...
Страница 264: ...MEMO...
Страница 265: ...Espa ol Italiano Fran ais Deutsch English 265 Operazioni avanzate...
Страница 291: ...Espa ol Italiano Fran ais Deutsch English 291 Funcionamiento b sico...
Страница 330: ...MEMO...
Страница 331: ...Espa ol Italiano Fran ais Deutsch English 331 Funcionamiento avanzado...
Страница 347: ...347 Appendices...
Страница 394: ...MEMO...