6
ENGLISH
USER/INSTALLER
TECHNICAL DATA
TECHNICAL DATA as per EN 14785
MILLA H 12
Nominal power
Reduced power
Available power
12,4
3,3
kW
Heat output to water
10,2
2,5
kW
Efficiency
93,0
93,2
%
CO emissions at 13% O
2
0,004
0,009
%
Smoke temperature
113
65
°C
Fuel consumption
2,8
0,7
kg/h
Tank capacity
24
kg
Recommended draught
14
Pa
Autonomy
9
34
ore
Water content
13
l
Maximum operating pressure
3
bar
Maximum operating temperature
90
°C
Heatable volume *
325
m
3
Smoke outlet diameter
80
mm
Air intake diameter
50
mm
Weight with packaging
220
kg
Energy efficiency classes
(2015-1186/1187 Regulation)
A++
TECHNICAL DATA FOR SIZING THE FLUE
which must in any case satisfy the requirements in this sheet and the installation instructions for the product
Nominal power
MILLA H 12
Fumes temperature at smoke outlet
136
°C
Minimum draw
0,01
Pa
Fumes flow rate
8,3
g/s
* A calorific value of 4.8 kW/Kg has been used to calculate consumption
** The heatable volume is calculated based on the assumption of a heating demand of 33 Kcal/m³ hour.
ELECTRICAL SPECIFICATIONS
Power supply
230 Vac +/- 10% 50 Hz
Power absorbed in stand by
70 - 39 - 4 W
Power absorption during ignition
300 W
Protection rating
Fusibile 4 AT, 250 Vac 5x20
Содержание MILLA H 12
Страница 1: ...EN Installation use and maintenance page 2 MILLA H 12 PELLET BOILER STOVE...
Страница 12: ...12 ENGLISH INSTALLATION EATING CONFIGURATION INSTALLER...
Страница 13: ...13 ENGLISH INSTALLATION BOILER CONFIGURATION INSTALLER...
Страница 14: ...14 ENGLISH INSTALLER INSTALLATION PUFFER CONFIGURATION...
Страница 41: ...41 ENGLISH...
Страница 42: ......
Страница 43: ......
Страница 44: ...code 942028 GB 03 19 A w w w e d i l k a m i n c o m 942028 GB...