- 29
-
OPERA
TION - USER
TROUBLESHOOTING
Problem
Cause
Corrective Action
There is a smell of fumes.
- Fumes are escaping into the air
- Check that the loading and
combustion chamber doors close
correctly
- Draught register
- Make sure it opens the primary air
damper
- Chain unhooked or broken
- Hook the chain back on
- Primary air register damper jammed
- Manually release the damper
- Load wood
- Follow the procedure described in
this manual
The boiler has reached the set
temperature but the radiators are
still cold
- Presence of air
- System components
- Contact the Technical Service
The boiler does not reach the set
temperature
- Draught register
- Make sure it opens the primary air
damper
- Chain unhooked or broken
- Hook the chain back on
- Primary air register damper jammed
- Manually release the damper
- Flue gas path and/or boiler dirty
- Clean the flue gas path
- Clean the boiler
- Load wood
- Follow the procedure described in
this manual
Flue gas emissions dark in colour
- Flue blocked
- Boiler dirty
- Ash collection container full
- Clean the flue gas path
- Clean the boiler
- Empty the container and clean the
ash collection chamber
- Draught register
- Make sure it opens the primary air
damper
- Unsuitable wood used (unseasoned)
- Use seasoned wood
(12-20% UR)
- Load wood
- Follow the procedure described in
this manual
In the boiler does not start operating normally, contact the Technical Service or other professionally qualified personnel.