- 15
-
INST
ALLA
TION
Diagram 3: ENERGY boiler, combined with another boiler, with energy accumulator to supply the systems
IAF
MI
CENTRAL HEATING
FLOW OUTLET
CENTRAL HEATING
RETURN INLET
RI
5
6
1
1
7
8
4
1
1
1
1
1
1
1
1
2
3
9
9
1
9
10
11
2
1
1
3
2
1
1
3
1
9
12
1 Disconnect valve
2 Pumps
3 Non-return valves
4 Outlet manifold
5 Return manifold
6 Open expansion vessel
7 Pressure reducer
8
Filter/softener
9 Drains
10 Energy accumulator
11 Vent valve
12 Optional min. temp. probe
for starting the pump
MI
Central heating flow outlet
RI
Central heating return inlet
IAF Cold water inlet
WARNING
•
The choice and installation of the components making up the system is left to the expertise of the installer, who must
operate in a workmanlike manner and according to the legislation in force.
•
The system must feature an open vessel and ensure a minimum head of 10 metres.
•
The boiler can be used for the production of domestic hot water when combined with a storage cylinder.
•
DO NOT INSTALL ON-OFF DEVICES ON THE SAFETY DISCHARGE.
1 Disconnect valve
2 Pumps
3 Non-return valves
4 Outlet manifold
5 Return manifold
6 Open expansion vessel
7 Pressure reducer
8
Filter/softener
9 Drains
10 Energy accumulator
11 Vent valve
12 Optional min. temp. probe
for starting the pump
MI
Central heating flow outlet
RI
Central heating return inlet
IAF Cold water inlet
ACS Domestic hot water
2
1
1
3
MI
ACS
CENTRAL HEATING
FLOW OUTLET
CENTRAL HEATING
RETURN INLET
RI
5
6
4
1
1
1
1
1
1
1
1
2
3
9
9
1
9
10
11
2
1
1
3
IAF
1
1
7
8
1
9
12
Diagram 4: ENERGY boiler, combined with a DHW storage cylinder, with energy accumulator to supply the systems
Содержание ENERGY 21
Страница 3: ...3 GENERAL...
Страница 31: ......