MMU-16LE
SmartMonitor
Operations Manual
Eberle Design Inc.
Page 28
5.2.2 MENU
Pressing the NEXT button followed by the SELECT button from the top level provides the
main Menu structure for selecting the following functions:
5.2.2.1 VIEW LOGS
This menu category provides a review of:
Previous Failure (PF) log
AC Line (AC) event log
Monitor Reset (MR) log
Events are stored with #1 being the newest event in the log. Pressing the NEXT button will
display the events from newest to oldest (#1 … #n). Once the last entry is displayed
pressing the NEXT button will display the events from oldest to newest (#n … #1).
The Diagnostic Wizard is automatically invoked when the HELP button is pressed while
reviewing the Previous Failure (PF) logs.
5.2.2.2 VIEW AND SET CONFIGURATION
This menu category provides a means to review and/or set configuration parameters:
Function
View
Set
Field Check Enable
Dual Indication Enable
Red Fail Enable
Unit Options
Permissive Channels
Program Card Options
Red+Yellow Clearance Disable
Monitor ID and Name
Firmware Version
Set-up Wizard
Set Factory Default
Configuration Check Value
Flashing Yellow Arrow Enable
PPLT5 Suppression Enable
See Section 6 for details on each item.
5.2.2.3 SET-UP WIZARD
The built-in Set-up Wizard (see Section 6.3.14) is used to generate configuration values for
the following parameters:
Field Check Enable (Type 16 mode only)
Red Fail Enable
Dual Indication Enable (RG, YG, and GY)
Minimum Yellow Plus Red Clearance
The following parameters are NOT
Unit Data
affected by the Set-up Wizard and must be manually
programmed:
Permissive Matrix (Program Card jumpers)
Minimum Yellow Clearance Disable (Program Card jumpers)
The permissive programming on the Program Card must still be provided for Conflict
monitoring. The MMU-16LE
SmartMonitor
®
will not exit the fault mode without the Program
Card inserted.