Installation
Observe the following guidelines when installing the EdgeMarc 4576:
Always verify that the AC cord is disconnected from a power source prior to
installation.
Do not stack multiple units on top of each other, as this can cause overheating.
Ensure that the installation site has adequate air circulation and meets the
minimum operating conditions for the system as specified in the
section of this document.
Required Tools and Cables
TIA/EIA 568B standard Ethernet cables to connect the LAN ports to LAN switches
or to individual IP phones. They can also be used to connect the Ethernet WAN
port to a WAN router, a cable modem or a DSL Modem, if a T1/E1 port is not being
used to connect to the WAN.
Philips screwdriver (if the unit will be mounted in a rack).
Male 50-pin Amphenol type connector (90 degree or 180 degree) to connect to the
FXS Phone ports. Not included.
Step 1: Install the EdgeMarc 4576 Chassis
1. Remove the EdgeMarc 4576 and accessories from the shipping container:
AC Power cord
Rack mount ears
6 Philips head screws to attach the rack mount ears to the chassis
Edgewater Documentation CD
Regulatory, Compliance, and Safety Information
2. Place the EdgeMarc 4576 on a flat, dry surface such as a desktop, shelf or tray, or
install it in a rack as described below.
Rack Mount Installation
You can install the EdgeMarc 4576
in a 19” rack using the rack mount kit supplied with
the product.
IMPORTANT:
Before completing rack installation of the EdgeMarc, take note of the
following conditions: