background image

22 

EdgeStar Limited Warranty 

One (1) Year Parts & Ninety (90) Days Labor

 

 

This product is warranted by EdgeStar to be free from defective workmanship and materials, subject to any conditions set forth as 
follows:

 

 

WHAT IS COVERED:

 

LABOR: For a period of NINETY (90) DAYS from the date of original purchase, labor will be performed free of charge at an 
authorized EdgeStar repair facility. At its option, EdgeStar will repair the product with new or remanufactured parts, or exchange 
the defective product with a new, refurbished, or remanufactured product. If a product is replaced, it will carry the remaining 
warranty of the original product. After the ninety (90) day period, EdgeStar will no longer be responsible for labor charges 
incurred. All defective products and parts covered by this warranty will be repaired or replaced on a mail-in basis to an EdgeStar 
authorized repair facility.

 

 

PARTS: For a period of ONE (1) YEAR from the date of original purchase, EdgeStar will supply new, rebuilt, or refurbished parts free 
of charge. EdgeStar may request a defective part be returned in exchange for the replacement part. All replacement parts or 
products will be new, remanufactured, or refurbished. All products and parts replaced by EdgeStar under warranty service 
become the property of EdgeStar.

 

 

This warranty applies to the original purchaser only, and only covers defects in workmanship experienced during operation of the 
product under normal service, maintenance, and usage conditions. This warranty applies to the purchase and use of this product 
in residential settings within the contiguous United States of America. 

 

 

WHAT IS NOT COVERED:

 

The following limitations apply to the coverage of this warranty. This warranty does not cover:

 

 

Labor charges for installation, setup or training to use the product.

 

 

Shipping damage, and any damage caused by improper packaging for shipment to an authorized service center, and any 
damaged caused by improper voltage or any other misuse, including abnormal service, handling, or usage.

 

 

Cosmetic damage such as scratches and dents.

 

 

Normal wear and tear on parts or replacement of parts designed to be replaced, e.g. filters, cartridges, batteries.

 

 

Service trips to deliver, pick-up, or repair, install the product, or to instruct in proper usage of the product.

 

 

Damages or operating problems resulting from misuse, abuse, operation outside environmental specifications, uses 
contrary to instructions provided in the owner’s manual, accidents, acts of God, vermin, fire, flood, improper installation, 
unauthorized service, maintenance negligence, unauthorized installation or modification, or rental or commercial use.

 

 

Labor, service transportation, and shipping charges incurred 91 days or more after the date of original purchase.

 

 

The use of EdgeStar products in commercial or rental settings.

 

 

Optional accessories, attachments, and appearance items.

 

 

Products that have been modified to perform outside of specifications without the prior written permission of EdgeStar.

 

 

Products lost in shipment, or theft.

 

 

Products sold AS IS or from an unauthorized reseller.

 

 

Products that have had their serial numbers removed or defaced. Products with serial numbers that have been invalidated.

 

 

Damage to personal property from use of product. 

 

 

Replacement of repair of household fuses, circuit breakers, wiring, or plumbing.

 

 

OBTAINING WARRANTY SERVICE:

 

If you believe your product is defective, contact EdgeStar Customer Support for troubleshooting assistance and warranty service at 

www.edgestar.com

 or 1-866-319-5473. Before contacting EdgeStar, have your serial number and proof of purchase available. Once an 

EdgeStar authorized representative has confirmed that your product is defective and eligible for warranty service, the product must be 

returned to an EdgeStar repair facility. The purchaser is solely responsible for prepaying all shipping related costs to and from the repair 
facility. EdgeStar is not responsible for damage resulting from shipper mishandling or improper packaging. Do not return a defective 
product to the place of purchase. Products received without a return authorization number will be refused.

 

 

 

THIS WARRANTY IS IN LIEU OF ANY OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING WITHOUT LIMITATION, ANY WARRANTY OF 
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. TO THE EXTENT ANY IMPLIED WARRANTY IS REQUIRED BY LAW, IT IS LIMITED IN DURATION 

TO THE EXPRESS WARRANTY PERIOD ABOVE. NEITHER THE MANUFACTURER NOR ITS DISTRIBUTORS SHALL BE LIABLE FOR ANY INCIDENTAL, 
CONSEQUENTIAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES OF ANY NATURE, INCLUDING WITHOUT LIMITATION, LOST REVENUES OR PROFITS, OR ANY 
OTHER DAMAGE WHETHER BASED IN CONTRACT, TORT, OR OTHERWISE. 

IN NO EVENT AND UNDER NO CIRCUMSTANCE OF ANY TYPE OR KIND SHALL 

THE SELLER, MANUFACTURER AND/OR DISTRIBUTOR BE LIABLE FOR ANY REASON, UNDER ANY THEORY, FOR MORE THAN THE BASIC COST OF 

THE PRODUCT TO THE PURCHASER OR END USER.

 

SOME STATES DO NOT ALLOW THE EXCLUSION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO 

THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS. YOU MAY HAVE OTHER RIGHTS THAT VARY 
FROM STATE TO STATE.

 

 

Содержание AP16000G

Страница 1: ...Portable Air Conditioner Owner s Manual For more information on other great EdgeStar products on the web go to http www edgestar com To use the EdgeStar self diagnostic tool go to https support edgestar com AP16000G ...

Страница 2: ...e the unit with a damaged plug or loose socket Use only the correct power supply with appropriate amperage If the power cord is damaged it must be replaced by the manufacturer a service agent or a qualified technician Do not remove any part of the casing unless you are instructed to do so by an authorized technician General Safety This portable air conditioner is not intended to be used by childre...

Страница 3: ... into a grounded outlet 2 Press the TEST button on the LCDI plug This should trip the plug and cut the power to the air conditioner If the plug does not trip and you are able to turn on the unit please contact EdgeStar support DO NOT USE YOUR PORTABLE AIR CONDITIONER IF THE TEST FAILS Press the RESET button to start using your air conditioner DO NOT use the TEST and RESET buttons as an ON OFF swit...

Страница 4: ...e Window Kit 4 Window Kit Installation Instructions 4 Installation of the Exhaust Hose 7 NOTES ABOUT THE EXHAUST HOSE 8 INSTALLING THE DRAIN HOSE 9 DRAINING THE UNIT 10 Direct Drainage 10 INSTALLING THE FILTER 10 OPERATING INSTRUCTIONS 11 Control Panel Overview 11 Remote Control 12 Modes and Features 13 MAINTENANCE 15 Cleaning the Exterior 15 Cleaning the Pre Filter 15 Preparation for Storage 15 E...

Страница 5: ... your unit and are needed to obtain warranty service You may also want to staple your receipt to this manual as it is the proof of your purchase and is also needed for service under your warranty Model Number Serial Number Date of Purchase For a more efficient experience please do the following before contacting customer service If you received a damaged product immediately contact the dealer that...

Страница 6: ...2 Parts Identification Front View Back View ...

Страница 7: ...Kit and Exhaust Hose Installation Parts Included Suggested Tools Philips Screw Driver Medium Size Tape Measure Ruler Scissors Saw in the event that your window panel needs to be cut down in size for installation ...

Страница 8: ...fficient power to your unit See the power requirements listed on the product label printed on the side or on the back of your portable air conditioner Your window kit can be installed on a horizontal or vertical sliding window as shown in the images below Please follow the installation instructions carefully to avoid personal injury or damage Window Kit Installation Instructions Step 1 Attach the ...

Страница 9: ...o the same width as the window frame opening o Open the window and place the window panel on the windowsill o Secure the window panel to the windowsill If the inner width of the window is between 24 and 36 inclusive o Open the window and place the adjustable window panel on the windowsill o Slide the adjustment panel to fit the window frame width Note The window panel cannot be installed in window...

Страница 10: ...me width o Secure the window panel to the windowsill with four large wood screws and four slider brackets Step 4 Cut the foam seal to the proper length and attach it to the top of the window panel Step 5 Close the window securely against the window panel Step 6 Cut the foam seal to an appropriate length between the top of the inner window and outer window Step 7 Attach the bracket with a screw ...

Страница 11: ...ip Rotate the hose counterclockwise into the rear clip Step 3 Install the hose at the joint A Aim the opening of hose at the round mouth of joint A Rotate the hose counterclockwise into joint A Step 4 Attach joint A to the back of the unit with the two cutouts on the joint Line them up over the two tabs on the air exhaust outlet and firmly slide the joint A down until it clicks To remove make sure...

Страница 12: ...ner can be extended up to approximately 48 inches however for maximum efficiency use the shortest length possible 2 Try to prevent any kinks or bends in the exhaust hose Kinks or bends may trap exhaust air which can radiate heat into the room or potentially cause the portable air conditioner to overheat and shut itself off 3 The exhaust hose supplied with the portable air conditioner has been spec...

Страница 13: ...rt with the screw Step 3 Attach one end of the drain hose to the drain port with the clip provided Step 4 Insert the rubber plug into the other end of the drain hose secure it with the pipe hoop and attach it to the drain pipe clip Note The drainage hose must be installed before using this unit If it is not a block can form in the drain and prevent the unit from functioning normally ...

Страница 14: ... drain plug from the drain port 2 Connect a drain hose to the drain port The portable air conditioner will now drain through the drain hose Please note that this unit has no drain pump all water will drain with gravity only i e only downhill Installing the Filter Your portable air conditioner ships with a carbon filter to help remove any unwanted odor from the room It is recommended you replace th...

Страница 15: ...exhaust hose and window kit must be installed when the unit is in Cool or Dry Mode Fan Speed When the unit is running in Cool or Fan mode press the arrow buttons to select the fan speed desired There are 4 fan settings High Middle Low and Auto Water Full When the unit is in Cool or Dry mode condensation will drain to the water reservoir When the water tank is full a buzzer will sound eight times i...

Страница 16: ...mer On This button enables an automatic start for a specific time of your choosing Timer Off This button enables an automatic shutoff for a specific time of your choosing Increase This button increases the set temperature or time Decrease This button decreases the set temperature or time Clock This button adjusts the clock X Fan This button enables X fan mode Note Be careful not to drop the remote...

Страница 17: ...button 5 Set the thermostat by using the and buttons on the remote The thermostat is adjustable between 61 F and 86 F in one degree increments Dry When dry mode or dehumidify mode is selected the air conditioner operates under dry mode at a low fan speed The Dry Indicator light will be lit Under dry mode the fan speed can t be adjusted Fan Fan Only mode is used to circulate the air in your room No...

Страница 18: ...set the unit to turn off at a certain time After pressing this button the icon disappears and the word OFF will blink on the remote Press the or button to adjust the Timer Off setting Pressing the or button will increase or decrease the time by 1 minute Hold the or button to quickly adjust the time Press the Timer OFF button again to confirm the time The word OFF will stop blinking and the icon wi...

Страница 19: ...oose dust and dirt then rinse thoroughly under lukewarm running water below 104 F You may use a mild soap and water solution if needed 4 Allow the pre filter to air dry in a cool and shaded place Dry the pre filter thoroughly before reinstalling it Clean the pre filter periodically If the unit is used in a dusty environment you may need to clean it on a weekly basis Preparation for Storage If you ...

Страница 20: ...unit in cooling mode for 3 or more hours to cool the room before you arrive You may want to operate the unit all day if you live in a warmer climate Minimize the heat sources direct sunlight computers servers people etc in the room Close all windows and doors Use the unit in a contained room For example operate the unit in a room with four walls and a ceiling instead of a partitioned studio or war...

Страница 21: ...rrectly The remote control is defective Contact customer service My air conditioner is making a loud noise The unit is not level Make sure the unit is on a level surface A foreign object has jammed the fan Remove the object from the fan The floor below the unit is uneven Move the unit to a level surface My air conditioner is making a continuous metallic knocking or pinging sound The unit may have ...

Страница 22: ...t to cool the area or use a larger unit There are open windows and doors Close any open doors or windows There are too many heat sources Remove or shut off additional heat sources such as radio equipment servers etc The room garage may be inadequately insulated Properly insulate the room to be cooled i e using fiberglass The ambient temperature is too high The unit may not work if the room tempera...

Страница 23: ...lfunction Please contact customer service F2 The evaporator temperature sensor has a malfunction Please contact customer service F0 Refrigerant is leaking or the system is blocked Please contact customer service H3 This is the overload protection for the compressor If the unit is working in a high temperature and high humidity environment power off the unit and start it after the ambient temperatu...

Страница 24: ...onditioner Model AP16000G Voltage Frequency AC 220 V 60 Hz Input Power 4835 W Current 9 7 A Cooling Capacity SACC 10000 BTU Cooling Capacity ASHRAE 16000 BTU Color Grey Coolant R 410A Timer 24 Hour Dimensions H x W x D 33 x 19 3 4 x 18 1 8 Weight 101 4 lbs ...

Страница 25: ... different standard ASHRAE that produced a higher cooling capacity output While the SACC BTU s are lower than the previous ASHRAE BTU s the construction and cooling capacity of this model s remains unchanged Both the SACC and ASHRAE ratings are included for consumer comparison What is SACC SACC or the Seasonally Adjusted Cooling Capacity is a rating in BTU hour that represents the weighted average...

Страница 26: ...cts of God vermin fire flood improper installation unauthorized service maintenance negligence unauthorized installation or modification or rental or commercial use Labor service transportation and shipping charges incurred 91 days or more after the date of original purchase The use of EdgeStar products in commercial or rental settings Optional accessories attachments and appearance items Products...