– 531 –
Figure 303: Configuring Detailed Settings for Maintenance Associations
C
ONFIGURING
M
AINTENANCE
E
ND
P
OINTS
Use the Administration > CFM (Configure MEP – Add) page to configure
Maintenance End Points (MEPs). MEPs, also called Domain Service Access
Points (DSAPs), must be configured at the domain boundary to provide
management access for each maintenance association.
CLI R
EFERENCES
◆
"CFM Commands" on page 1319
C
OMMAND
U
SAGE
◆
CFM elements must be configured in the following order: (1)
maintenance domain at the same level as the MEP to be configured
(see
"Configuring CFM Maintenance Domains"
), (2) maintenance
association within the domain (see
"Configuring CFM Maintenance
Associations"
), and (3) finally the MEPs using the MEP List.
◆
An interface may belong to more than one domain, or to different MAs
in different domains.
◆
To change the MEP’s MA or the direction it faces, first delete the MEP,
and then create a new one.
P
ARAMETERS
These parameters are displayed:
◆
MD Index
– Domain index. (Range: 1-65535)
◆
MA Index
– MA identifier. (Range: 1-2147483647)
◆
MEP ID
– Maintenance end point identifier. (Range: 1-8191)
◆
MEP Direction
– Up indicates that the MEP faces inward toward the
switch cross-connect matrix, and transmits CFM messages towards,
Содержание ES3528MV2
Страница 1: ...Management Guide www edge core com ES3528MV2 ES3528MV2 DC 28 Port Fast Ethernet Layer 2 Switch...
Страница 2: ......
Страница 4: ......
Страница 48: ...CONTENTS 48...
Страница 68: ...SECTION I Getting Started 68...
Страница 78: ...CHAPTER 1 Introduction System Defaults 78...
Страница 96: ...SECTION II Web Configuration 96...
Страница 116: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 116...
Страница 148: ...CHAPTER 4 Basic Management Tasks Resetting the System 148...
Страница 192: ...CHAPTER 5 Interface Configuration VLAN Trunking 192 Figure 65 Configuring VLAN Trunking...
Страница 226: ...CHAPTER 6 VLAN Configuration Configuring VLAN Translation 226...
Страница 236: ...CHAPTER 7 Address Table Settings Configuring MAC Address Mirroring 236...
Страница 270: ...CHAPTER 9 Congestion Control Automatic Traffic Control 270...
Страница 300: ...CHAPTER 11 Quality of Service Attaching a Policy Map to a Port 300...
Страница 418: ...CHAPTER 13 Security Measures DHCP Snooping 418...
Страница 588: ...CHAPTER 15 IP Configuration Setting the Switch s IP Address IP Version 6 588...
Страница 606: ...CHAPTER 16 IP Services Configuring the PPPoE Intermediate Agent 606...
Страница 676: ...CHAPTER 17 Multicast Filtering Multicast VLAN Registration for IPv6 676...
Страница 772: ...CHAPTER 20 System Management Commands Switch Clustering 772...
Страница 802: ...CHAPTER 22 Remote Monitoring Commands 802...
Страница 808: ...CHAPTER 23 Flow Sampling Commands 808...
Страница 872: ...CHAPTER 24 Authentication Commands PPPoE Intermediate Agent 872...
Страница 950: ...CHAPTER 25 General Security Measures Port based Traffic Segmentation 950...
Страница 1002: ...CHAPTER 27 Interface Commands Power Savings 1002...
Страница 1016: ...CHAPTER 28 Link Aggregation Commands Trunk Status Display Commands 1016...
Страница 1046: ...CHAPTER 30 Congestion Control Commands Automatic Traffic Control Commands 1046...
Страница 1058: ...CHAPTER 32 UniDirectional Link Detection Commands 1058...
Страница 1064: ...CHAPTER 33 Address Table Commands 1064...
Страница 1124: ...CHAPTER 35 ERPS Commands 1124...
Страница 1168: ...CHAPTER 36 VLAN Commands Configuring Voice VLANs 1168...
Страница 1182: ...CHAPTER 37 Class of Service Commands Priority Commands Layer 3 and 4 1182...
Страница 1202: ...CHAPTER 38 Quality of Service Commands 1202...
Страница 1360: ...CHAPTER 41 CFM Commands Delay Measure Operations 1360...
Страница 1382: ...CHAPTER 43 Domain Name Service Commands 1382...
Страница 1440: ...SECTION IV Appendices 1440...
Страница 1468: ...COMMAND LIST 1468...
Страница 1479: ......
Страница 1480: ...ES3528MV2 ES3528MV2 DC E112013 ST R03...