– 1319 –
41
CFM C
OMMANDS
Connectivity Fault Management (CFM) is an OAM protocol that includes
proactive connectivity monitoring using continuity check messages, fault
verification through loop back messages, and fault isolation by examining
end-to-end connections between provider edge devices or between
customer edge devices.
CFM is implemented as a service level protocol based on service instances
which encompass only that portion of the metropolitan area network
supporting a specific customer. CFM can also provide controlled
management access to a hierarchy of maintenance domains (such as the
customer, service provider, and equipment operator).
The following list of commands support functions for defining the CFM
structure, including domains, maintenance associations, and maintenance
access points. It also provides commands for fault detection through
continuity check messages for all known maintenance points, and cross-
check messages for statically configured maintenance points located on
other devices. Fault verification is supported through loop back messages,
and fault isolation through link trace messages. Fault notification is also
provided by SNMP alarms which are automatically generated by
maintenance points when connectivity faults or configuration errors are
detected in the local maintenance domain.
Table 177: CFM Commands
Command
Function
Mode
Defining CFM Structures
ethernet cfm ais level
Configures the maintenance level at which Alarm
Indication Signal information will be sent
GC
ethernet cfm ais ma
Enables the MEPs within the specified MA to send
frames with AIS information
GC
ethernet cfm ais period
Configures the interval at which AIS information is
sent
GC
ethernet cfm ais suppress
alarm
Suppresses AIS messages following the detection of
defect conditions
GC
ethernet cfm domain
Defines a CFM maintenance domain, sets the
authorized maintenance level, and enters CFM
configuration mode; also specifies the MIP creation
method for MAs within this domain
GC
ethernet cfm enable
Enables CFM processing globally on the switch
GC
ma index name
Creates a maintenance association within the current
maintenance domain, maps it to a customer service
instance, and sets the manner in which MIPs are
created for this service instance
CFM
ma index name-format
Specifies the name format for the maintenance
association as IEEE 802.1ag character based, or ITU-T
SG13/SG15 Y.1731 defined ICC-based format
CFM
Содержание ES3528MV2
Страница 1: ...Management Guide www edge core com ES3528MV2 ES3528MV2 DC 28 Port Fast Ethernet Layer 2 Switch...
Страница 2: ......
Страница 4: ......
Страница 48: ...CONTENTS 48...
Страница 68: ...SECTION I Getting Started 68...
Страница 78: ...CHAPTER 1 Introduction System Defaults 78...
Страница 96: ...SECTION II Web Configuration 96...
Страница 116: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 116...
Страница 148: ...CHAPTER 4 Basic Management Tasks Resetting the System 148...
Страница 192: ...CHAPTER 5 Interface Configuration VLAN Trunking 192 Figure 65 Configuring VLAN Trunking...
Страница 226: ...CHAPTER 6 VLAN Configuration Configuring VLAN Translation 226...
Страница 236: ...CHAPTER 7 Address Table Settings Configuring MAC Address Mirroring 236...
Страница 270: ...CHAPTER 9 Congestion Control Automatic Traffic Control 270...
Страница 300: ...CHAPTER 11 Quality of Service Attaching a Policy Map to a Port 300...
Страница 418: ...CHAPTER 13 Security Measures DHCP Snooping 418...
Страница 588: ...CHAPTER 15 IP Configuration Setting the Switch s IP Address IP Version 6 588...
Страница 606: ...CHAPTER 16 IP Services Configuring the PPPoE Intermediate Agent 606...
Страница 676: ...CHAPTER 17 Multicast Filtering Multicast VLAN Registration for IPv6 676...
Страница 772: ...CHAPTER 20 System Management Commands Switch Clustering 772...
Страница 802: ...CHAPTER 22 Remote Monitoring Commands 802...
Страница 808: ...CHAPTER 23 Flow Sampling Commands 808...
Страница 872: ...CHAPTER 24 Authentication Commands PPPoE Intermediate Agent 872...
Страница 950: ...CHAPTER 25 General Security Measures Port based Traffic Segmentation 950...
Страница 1002: ...CHAPTER 27 Interface Commands Power Savings 1002...
Страница 1016: ...CHAPTER 28 Link Aggregation Commands Trunk Status Display Commands 1016...
Страница 1046: ...CHAPTER 30 Congestion Control Commands Automatic Traffic Control Commands 1046...
Страница 1058: ...CHAPTER 32 UniDirectional Link Detection Commands 1058...
Страница 1064: ...CHAPTER 33 Address Table Commands 1064...
Страница 1124: ...CHAPTER 35 ERPS Commands 1124...
Страница 1168: ...CHAPTER 36 VLAN Commands Configuring Voice VLANs 1168...
Страница 1182: ...CHAPTER 37 Class of Service Commands Priority Commands Layer 3 and 4 1182...
Страница 1202: ...CHAPTER 38 Quality of Service Commands 1202...
Страница 1360: ...CHAPTER 41 CFM Commands Delay Measure Operations 1360...
Страница 1382: ...CHAPTER 43 Domain Name Service Commands 1382...
Страница 1440: ...SECTION IV Appendices 1440...
Страница 1468: ...COMMAND LIST 1468...
Страница 1479: ......
Страница 1480: ...ES3528MV2 ES3528MV2 DC E112013 ST R03...