C
HAPTER
14
| Basic Administration Protocols
Ethernet Ring Protection Switching
– 499 –
over both ring ports, informing that no request is present at this
ring node and initiates a guard timer. When another recovered ring
node (or nodes) holding the link block receives this message, it
compares the Node ID information with its own Node ID. If the
received R-APS (NR) message has the higher priority, this ring node
unblocks its ring ports. Otherwise, the block remains unchanged. As
a result, there is only one link with one end blocked.
The ring nodes stop transmitting R-APS (NR) messages when they
accept an R-APS (NR, RB – RPL Blocked), or when another higher
priority request is received.
■
Recovery with Revertive Mode – When all ring links and ring
nodes have recovered and no external requests are active,
reversion is handled in the following way:
a.
The reception of an R-APS (NR) message causes the RPL
Owner Node to start the WTR (Wait-to-Restore) timer.
b.
The WTR timer is cancelled if during the WTR period a higher
priority request than NR is accepted by the RPL Owner Node
or is declared locally at the RPL Owner Node.
c.
When the WTR timer expires, without the presence of any
other higher priority request, the RPL Owner Node initiates
reversion by blocking its traffic channel over the RPL,
transmitting an R-APS (NR, RB) message over both ring
ports, informing the ring that the RPL is blocked, and
performing a flush FDB action.
d.
The acceptance of the R-APS (NR, RB) message causes all
ring nodes to unblock any blocked non-RPL link that does not
have an SF condition. If it is an R-APS (NR, RB) message
without a DNF (do not flush) indication, all ring nodes flush
the FDB.
■
Recovery with Non-revertive Mode – In non-revertive operation,
the ring does not automatically revert when all ring links and
ring nodes have recovered and no external requests are active.
Non-revertive operation is handled in the following way:
a.
The RPL Owner Node does not generate a response on
reception of an R-APS (NR) messages.
b.
When other healthy ring nodes receive the NR (Node ID)
message, no action is taken in response to the message.
c.
When the operator issues the Clear command (Configure
Operation page) for non-revertive mode at the RPL Owner
Node, the non-revertive operation is cleared, the RPL Owner
Node blocks its RPL port, and transmits an R-APS (NR, RB)
message in both directions, repeatedly.
d.
Upon receiving an R-APS (NR, RB) message, any blocking
node should unblock its non-failed ring port. If it is an R-APS
(NR, RB) message without a DNF indication, all ring nodes
flush the FDB.
Содержание ES3528MV2
Страница 1: ...Management Guide www edge core com ES3528MV2 ES3528MV2 DC 28 Port Fast Ethernet Layer 2 Switch...
Страница 2: ......
Страница 4: ......
Страница 48: ...CONTENTS 48...
Страница 68: ...SECTION I Getting Started 68...
Страница 78: ...CHAPTER 1 Introduction System Defaults 78...
Страница 96: ...SECTION II Web Configuration 96...
Страница 116: ...CHAPTER 3 Using the Web Interface Navigating the Web Browser Interface 116...
Страница 148: ...CHAPTER 4 Basic Management Tasks Resetting the System 148...
Страница 192: ...CHAPTER 5 Interface Configuration VLAN Trunking 192 Figure 65 Configuring VLAN Trunking...
Страница 226: ...CHAPTER 6 VLAN Configuration Configuring VLAN Translation 226...
Страница 236: ...CHAPTER 7 Address Table Settings Configuring MAC Address Mirroring 236...
Страница 270: ...CHAPTER 9 Congestion Control Automatic Traffic Control 270...
Страница 300: ...CHAPTER 11 Quality of Service Attaching a Policy Map to a Port 300...
Страница 418: ...CHAPTER 13 Security Measures DHCP Snooping 418...
Страница 588: ...CHAPTER 15 IP Configuration Setting the Switch s IP Address IP Version 6 588...
Страница 606: ...CHAPTER 16 IP Services Configuring the PPPoE Intermediate Agent 606...
Страница 676: ...CHAPTER 17 Multicast Filtering Multicast VLAN Registration for IPv6 676...
Страница 772: ...CHAPTER 20 System Management Commands Switch Clustering 772...
Страница 802: ...CHAPTER 22 Remote Monitoring Commands 802...
Страница 808: ...CHAPTER 23 Flow Sampling Commands 808...
Страница 872: ...CHAPTER 24 Authentication Commands PPPoE Intermediate Agent 872...
Страница 950: ...CHAPTER 25 General Security Measures Port based Traffic Segmentation 950...
Страница 1002: ...CHAPTER 27 Interface Commands Power Savings 1002...
Страница 1016: ...CHAPTER 28 Link Aggregation Commands Trunk Status Display Commands 1016...
Страница 1046: ...CHAPTER 30 Congestion Control Commands Automatic Traffic Control Commands 1046...
Страница 1058: ...CHAPTER 32 UniDirectional Link Detection Commands 1058...
Страница 1064: ...CHAPTER 33 Address Table Commands 1064...
Страница 1124: ...CHAPTER 35 ERPS Commands 1124...
Страница 1168: ...CHAPTER 36 VLAN Commands Configuring Voice VLANs 1168...
Страница 1182: ...CHAPTER 37 Class of Service Commands Priority Commands Layer 3 and 4 1182...
Страница 1202: ...CHAPTER 38 Quality of Service Commands 1202...
Страница 1360: ...CHAPTER 41 CFM Commands Delay Measure Operations 1360...
Страница 1382: ...CHAPTER 43 Domain Name Service Commands 1382...
Страница 1440: ...SECTION IV Appendices 1440...
Страница 1468: ...COMMAND LIST 1468...
Страница 1479: ......
Страница 1480: ...ES3528MV2 ES3528MV2 DC E112013 ST R03...