Quick Start Guide
– 4 –
Hardware Specifications
Router Chassis
Size (WxDxH)
440 x 300 x 44 mm (17.32 x 11.81 x 1.73 in.)
Weight
5.35 kg (11.79 lb), with two installed PSUs
Temperature
Operating: -40° C to 65° C (-40° F to 149° F)
Transportation: -40° C to 70° C (-40° F to 158° F)
Storage: -40° C to 70° C (-40° F to 158° F)
Humidity
Operating: 5% to 95% (non-condensing)
Power
Capacity
290 Watts maximum
48 VDC PSU
Power Rating
-48 VDC, 300 Watts
DC Input
-36 V – -72 V, 10 A
AC PSU
AC Input
100–240 VAC, 50/60 Hz, 5 A maximum
Regulatory Compliances
Emissions
EN 55032:2015+AC:2016, Class A
EN 61000-3-2:2014, Class A
EN 61000-3-3:2013
EN 300 386 V1.6.1
EN 301 489-1 V2.1.1
EN 301 489-19 V2.1.0
EN 303 413 V1.1.1
FCC Title 47, Part 15, Subpart B, Class A
Radio Equipment Directive 2014/53/EU
VCCI-CISPR 32:2016, Class A
BSMI Class A, CNS 13438
CCC GB 9254-2008, Class A
Immunity
EN 55035:2017
EN 55024:2010+A1:2015
IEC 61000-4-2/3/4/5/6/8/11
Environmental
Storage:
◆
ETSI EN 300 019-1-1 Class 1.1
◆
Temperature: -40° C to 70° C (-40° F to 158° F)
Transportation:
◆
ETSI EN 300 019-1-2 Class 2.3
◆
Temperature: -40° C to 70° C (-40° F to 158° F)
Operating Conditions:
◆
ETSI EN 300 019-1-3 Class 3.2
◆
Temperature: -40° C to 65° C (-40° F to 149° F)
◆
Relative Humidity: 5% to 95%
Safety
UL (CSA 22.2 No 62368-1 & UL 62368-1)
CB (IEC/EN 60950-1 & IEC/EN 62368-1)
BSMI CNS14336-1
CCC GB4943.1-2011